Lumina 17
Installer
29
Pre-run time
Setting of the time in which the air inlets go to the required position, before the fans
activate.
During Nat.Vent
Setting indicating if the extra inlets are open or closed during natural ventilation.
•
CLOSED
: close (normal setting)
•
FOLLOW INLET
: if the extra inlet has to 'follow' the normal air inlet (for example for
extra curtains that must also open with natural ventilation).
INSTALLER
VENTILATION
INLETS
tab page
Natural
Combi start/stop
Position low
Setting of transitional position when a switch is made from very low mechanical ventilation
to natural ventilation. The corresponding temperature is shown between brackets (based
on the actual settings).
Combi start/stop
Position high
Setting of the transitional position when a switch is made from natural ventilation to strong
mechanical ventilation. The corresponding temperature is shown between brackets
(based on the actual settings).
Damping
Setting of the opening/closing speed of air inlets during natural ventilation.
Min. Waittime
Setting of the minimum wait time for transition. Within this time the controller cannot go
back to natural ventilation.
6.2
Heating, cooling and humidification
6.2.1
Settings heating controls
INSTALLER
HEAT COOL HUM
tab page
Heat
Description
Setting of the name of the function.
Temp. Inputs
Setting the addresses of the analog inputs. If the temperature sensors have not been
assigned, the control computer will use the house temperature.