FAITHTECH
FTB9000 USER MANUAL
52
which can realize the output voltage rise and fall according to the set slope. This function
is suitable for use as a DC power supply.
Procedure of operation
1. press
button
,
Enter the Test function selection screen
;
2. Scroll the knob
,
select“RAMP”
,
press
button, Enter the "RAMP" function
parameter setting screen as follows:
Photo 3- 17 RAMPfunction parameters setting
3. Set the "RAMP" function parameters, the parameters are described in Table 3-6
voltage slow rise and slow fall function parameters;
4. press
button,Start "RAMP" function output
。
Table 3- 6Voltage slow rise and slow fall function parameter description table
name
Parameter Description
Current setting
Output current value, range: 0 ~ maximum output
current
Power setting
Output power value, range: 0 to the maximum output
power
voltage a
Set the voltage value of point a, ranging from 0 to
maximum output voltage
voltage b
Set the voltage value of point b, ranging from 0 to
maximum output voltage
voltage c
Set the voltage value of point c, ranging from 0 to
maximum output voltage