FAITHTECH
FTB9000 USER MANUAL
10
accuracy
1%F.S.
External analog programming
①
Control voltage
0~5V & 0~100%F.S.
Voltage
accuracy
0.5%F.S.
Accuracy of
current
0.5%F.S.
Linear adjustment rate
②
Voltage
0.01%F.S.
Current
0.05%F.S.
Load adjustment rate
③
Voltage
0.02%F.S.
Current
0.05%F.S.
Voltage measurement
①
resolution
16bits
accuracy
0.05%+0.05%F.S.
Current measurement
①
resolution
16bits
accuracy
0.1%+0.1% F.S.
Resistance measurement
①
resolution
0.001Ω
accuracy
1%+0.5%I.F.S.
Power measurement
①
accurancy
1%F.S.
Output noise & ripple
④
Voltage ripple
Vpp
10kW
1600mV
15kW
2400mV
3600mV
Voltage ripple
rms
10kW
350mV
15kW
400mV
400mV
Voltage rising slope
Maximum slope
40000V/s
Voltage drop time
no load
<
10s
full load
≤30ms
Transient
response
With 10%~90% dynamic load change, it takes less than 2ms for the equipment
voltage to recover to 0.75% accuracy range of the rated value
Parallel
machine
It supports 10 master and slave parallel machines of the same model
Protection
Over voltage, over current, over power, over temperature, under voltage, etc
Communication
interface
LAN
、
USB serial port
(
optional GPIB
、
CAN
、
RS485
)
Communication
SCPI
、
Modbus
、
CAN-Open protocol