Address
Description
Min/Max
Units
Read/
Write
Address:100701 ( 1895D hex
Format:
Note: The Trip Number shown in
PNU Name is a decimal value
701-710
Sensing Fault Trip
One or more of the internal
control thyristors (SCRs) have
failed to turn on properly.
The Unit has detected that the
SCRs are not operating as
expected.
Check connections all incoming
and outgoing connections.
R
Address:100801 ( 189C1 hex
Format:
Note: The Trip Number shown in
PNU Name is a decimal value
801-802
Fan Problem
One or more of the internal
cooling fans has failed
To ensure the heatsink is cooled
sufficiently the Unit Will trip if the
fans fail to operate
Check Unit fans for signs of
damage or contamination
R
Address:101001 ( 18A89 hex
Format:
Note: The Trip Number shown in
PNU Name is a decimal value
1001
Short Circuit Thyristor
One or more of the internal
control thyristors (SCRs) have
failed short circuit
The Unit has detected that the
SCRs are not operating as
expected.
ISOLATE SUPPLY.
Check by measuring the resistance
between L1-T1 L2-T2 L3-T3 (
Anything < 10R is assumed short
circuit)
R
Address:101101 ( 18AED hex
Format:
Note: The Trip Number shown in
PNU Name is a decimal value
1101
Low Current Trip
The motor current has been lower
than the low trip level for the low
trip time
This trip is not active during soft
start and soft stop and is "off" by
default.
If the low current trip is not
required turn "off" in "Trip
Settings".
R
Address:101201 ( 18B51 hex
Format:
Note: The Trip Number shown in
PNU Name is a decimal value
1201
Current Limit Timeout Trip
The motor has been held in
current limit longer than the "Start
current limit Time"
It is likely that the current limit
level has been set too low for the
application.
Increase the current limit level or
timeout period.
R
5. Modbus RTU Parameter Table (continued)
Содержание synergy
Страница 1: ...Innovation in soft start technology synergytm USER MANUAL MAN SGY 017 Version 01...
Страница 20: ...Synergy Series Soft Start User Manual MAN SGY 017 Version 01 25 07 2016 20 Blank Page...
Страница 27: ...Synergy Series Soft Start User Manual MAN SGY 017 Version 01 25 07 2016 27 Blank Page...
Страница 33: ...Synergy Series Soft Start User Manual MAN SGY 017 Version 01 27 06 2016 33 Blank Page...
Страница 84: ...Synergy Series Soft Start User Manual MAN SGY 017 Version 01 27 06 2016 84 Blank Page...
Страница 100: ...Synergy Series Soft Start User Manual MAN SGY 017 Version 01 27 06 2016 100 Blank Page...
Страница 106: ...Synergy Series Soft Start User Manual MAN SGY 017 Version 01 27 06 2016 106 Blank Page...
Страница 112: ...Synergy Series Soft Start User Manual MAN SGY 017 Version 01 27 06 2016 112 Blank Page...
Страница 129: ...Synergy Series Soft Start User Manual MAN SGY 017 Version 01 27 06 2016 129 Blank Page...
Страница 197: ...Synergy Series Soft Start User Manual MAN SGY 017 Version 01 27 06 2016 197 Blank Page...
Страница 204: ...Synergy Series Soft Start User Manual MAN SGY 017 Version 01 27 06 2016 204 Blank Page...
Страница 231: ...Synergy Series Soft Start User Manual MAN SGY 017 Version 01 27 06 2016 231 Notes...
Страница 232: ...Synergy Series Soft Start User Manual MAN SGY 017 Version 01 27 06 2016 232 Notes...
Страница 233: ...Synergy Series Soft Start User Manual MAN SGY 017 Version 01 27 06 2016 233...