background image

7

22 23

100 n   K 630

100 n   K 630

13

5

21

A

1

24

6

22

A

2

13

5

21

A

1

24

62

2

A

2

1 2

3

4

5

M

16 17 18

19 20

21 22 23

R

S

T

THREE-
PHASE
ELECTRIC
MOTOR

230 V - 25 W max. FLASHING LAMP

SUPPLY VOLTAGE
230 - 400 V 

±

 10%

THREE-PHASE

HIGH VOLTAGE
10 A - 380 V
FUSES

POWER CONTACTOR
"

OPEN

"

POWER CONTACTOR
"

CLOSE

"

PLUS

10

SLIDING GATES - THREE-PHASE

Содержание FIBO 300

Страница 1: ...G B INSTALLATION MANUAL...

Страница 2: ...ion for intense opening closing cycles The drive shaft is in direct contact with a mechanical torque control device worm and gear are made of bronze and steel and are supported by bearings in an oil b...

Страница 3: ...THE PLUGS ONCE THE PLUG PROTRUSION HAS BEEN ESTABLISHED TIGHTEN THE NUT TO THE FLOOR IN ORDER TO FIRMLY FIX THE PLUG IN THE HOLE THEN UNSCREW AND REMOVE THE NUT INSERT THE PLUGS IN THE HOLES LEAVING A...

Страница 4: ...te Pic 6 Temporarily clamp the rack to the gate levelling it using a spirit level for the entire length of the gate the rack must mesh the idle Fibo 300 driving gear I smoothly and without friction Th...

Страница 5: ...located on the front beneath the electric power panel E P P tighten in order to increase the torque and loosen in order to reduce the torque Pic 10 PIC 8 PIC 9 RACK SPARE RACK AS A PITCH GAGE IMPORTA...

Страница 6: ...ING ON AUTOMATIC CLOSING ON PREFLASHING ACTIVATED ON RADIO STEP BY STEP STOP IN BETWEEN ON DEAD MAN CONTROL Dip 4 OFF and Dip 3 OFF ON NO LAMP ON DURING DWELL TIME OFF NO FUNCTION EXT TIME PEDESTRIAN...

Страница 7: ...21 A 1 2 4 6 22 A 2 1 2 3 4 5 M 16 17 18 19 20 21 22 23 R S T THREE PHASE ELECTRIC MOTOR 230 V 25 W max FLASHING LAMP SUPPLY VOLTAGE 230 400 V 10 THREE PHASE HIGH VOLTAGE 10 A 380 V FUSES POWER CONTAC...

Страница 8: ...d Bridge terminals 3 and 6 if no key or push button switches are required N W To fit extra accessories such as lights CCTV etc use only solid state relays to prevent damages to the microprocessor DIP...

Страница 9: ...13 13 17 10 15 16 14 PIC 12 Holdonswitched Deadman control Pedestrian Opening Trimmer T3 OPERATING MODES from 3 to 30s It can be activated by any pulse eg by remote control superior to 2s 3 DIP SWITCH...

Страница 10: ...provided Pic 11 and Pic 15 following the Elpro 10 PLUS function logic description Drwg 3499 p 6 E P P ELECTRIC POWER PANEL WITH THE ELPRO 10 PLUS PROGRAMMER INCORPORATED SUPPORT PREPARED FOR ATTACHING...

Страница 11: ...cles a year 8 hours a day 131 000 FIBO 300 GEAR MOTOR Output revolutions 40 7 rpm Drive gear Z 24 Module 4 0 Ratio 1 32 Maximum nominal torque 128 Nm Transfer speed 12 m min Hydraulic oil type AGIP RO...

Страница 12: ...isconnect the mains switch before opening the electrical wire junction box cover The whole automation should be earthed with the yellow green wire We recommend reading the Safety Norms suggestions and...