Fibo 300 is fitted with a
safety system
that is activated upon opening the front cover door, through an “NC” power cut-off switch which,
for automations without an installed electric panel, must be connected to the Elpro 10 PLUS programmer, terminals 14-15 (Pic. 10 and
Pic. 11); it is also necessary to earth the entire system (Pic. 14).
SEPARATE LIMIT SWITCH ELECTRICAL CONNECTIONS
Fibo 300 has two independent limit switches, protected and isolated from outside (Pic. 15) and not connected to the electric panel
“E.P.P.”, therefore once the protection cover has been removed (Pic. 2, p. 2), it is necessary to implement the wiring in keeping with
the diagrams provided (Pic. 11 and Pic. 15) following the Elpro 10 PLUS function logic description, Drwg. 3499 p. 6.
“E.P.P.”
ELECTRIC POWER PANEL
WITH THE ELPRO 10 PLUS PROGRAMMER
INCORPORATED
SUPPORT PREPARED FOR ATTACHING THE
POWER PANEL AND ALL THE ELECTRICAL
CONNECTIONS TO THE PROGRAMMER
“N.C.”
LOW VOLTAGE CUT-OFF SWITCH
UPON OPENING THE
FIBO 300 DOOR,
CONNECTED TO TERMINALS 14-15
OF THE ELPRO 10 PLUS PROGRAMMER
EARTH
CONNECTION SYSTEM
“OPENING”
LIMIT SWITCH
“CLOSING”
LIMIT SWITCH
ELPRO 10 PLUS TERMINAL BOX (Pic. 11)
NEUTRAL
1 2 3 4 5 6 7 8 9 10111213
16 17 18 19 20
21 22 23
DANGER
L2 L3 L4 L5 L8 L9 L7 L6
8A 8A 8A
OPEN
RELAY
RADIO CONNECTOR
28
FADINI
27
26
630mA
ELPRO10plus 1.4
MICROPROCESSOR
VOLTAGE CHANGE
230V/400V
ON
OFF
DIP-SWITCH
1 2
3 4
3
630 mA
L10
L1
1A
5 6
7 8
EXT
TIME
PEDESTRIAN
OPENING
TIME
DWELL
TIME
MOTOR
RUN
TIME
RS RS
CLOSE
RELAY
LINE
RELAY
ELPRO 10 PLUS