5
PIC. 10
INSTALLATION OF LIMIT SWITCH STRIKE PLATES “F’
In order to stop the gate’s movement, the Fibo 300 has two hermetic roller tip limit switches positioned behind the automation, one of
which operates during closing and one during opening (Pic. 5).
The two
strike plates “F”
for stopping gate movement during opening and closing must be fixed to the gate by screws (Pic. 9), in such
a position that the
limit switch
roller tips
come into action as soon as they meet the strike plates “F”.
TORQUE CONTROL AND ADJUSTMENT
In order to adjust the operator torque, open the door with the customized key, then use a 27 mm box spanner “M” on the
M18 self-
locking nut
located on the front beneath the electric power panel “E.P.P.”: tighten in order to increase the torque and loosen in order
to reduce the torque (Pic. 10).
PIC. 8
PIC. 9
RACK
SPARE RACK AS A PITCH GAGE
IMPORTANT
: IN THE JOINT BETWEEN THE RACK RODS
MAKE SURE YOU RESPECT THE PITCH BETWEEN THE TEETH,
USING A SPARE RACK DURING THE ASSEMBLY PHASE
IN ORDER TO OBTAIN THE CORRECT SHAPE
LIMIT SWITCH STRIKE PLATE
FIXTURE TO THE RACK
BY SCREWS
“F”
LIMIT SWITCH
STRIKE PLATE
RACKS
WELDED TOGETHER
INCORPORATED
LIMIT SWITCH
LIMIT SWITCH
ROLLER TIPS
M18 SELF-LOCKING NUT
FOR MANUAL RELEASE AND
TORQUE ADJUSTMENT
“N.C.”
POWER CUT-OFF SWITCH
UPON OPENING THE
PROTECTION COVER
DOOR
ELECTRIC POWER
PANEL SUPPORT
TIGHTENING
THE M18 NUT
INCREASES
THE
SHAFT DRIVING FORCE
LOOSENING
THE M18 NUT
REDUCES
THE SHAFT DRIVING FORCE
“E.P.P.”
ELECTRIC POWER
PANEL
“M”
RELEASE
BOX SPANNER
Содержание FIBO 300