Mini-Mag Service Manual V1.0
13
13-5
CENTRAL COMMAND CONTROLLER
DIAGNOSING THE CONTROL SYSTEM
The Central Command II system with all its robust capabilities is also very easy to diagnose
and repair. To diagnose the system a clamp type DC amp meter and high impedance DC
Volt meter are required. The machine’s LCD display will also be utilized. It is important
never to use jumper wires connected to battery power or ground for testing as this can
instantly destroy the controller.
The controller is not field serviceable in any way and needs to be replaced in the event of
failure.
METERS
It is important to use a high quality meter when diagnosing the control systems on our
equipment as a low quality meter can ruin a controller just by taking a measurement. A
good rule of thumb is if you didn’t pay at least $50 for your meter don’t use it on our equip-
ment. NEVER use analog meters for diagnosing the controller systems on our machines
as they WILL damage the machine. A DC amp clamp is imperative for diagnosis of the
control systems, most DC amp clamps have a built in DC volt meter too. In addition to your
meter(s) you should have a quality set of test leads that have alligator clamps on the ends.
MEASUREMENTS
When measuring for voltage in the control system unless otherwise specified you will al-
ways set your meter to the DC volts scale and connect your negative ( - ) test lead to the
negative ( - ) battery cable or buss bar. When measuring for amp draw you will always
measure around ONLY 1 wire ( + ) OR ( - ) going to the device in question. Place the meter
clamp on the wire with power off to the device. Zero out the meter and then power up the
device and take your readings.
LCD DISPLAY
The LCD is a critical component and can cause the machine to operate improperly or not
operate at all, There is a computer data link that is established between the LCD and the
computer when the machine is powered on and all the computer information is routed in
a loop through the LCD display. For this reason if an LCD fails it can cause a variety of
results from making the machine not turn on to making it not turn off.
INPUTS
The switches in the Central Command II System receive reference voltages from the con-
troller and then send signals, in the form of low or high voltage, to the controller. The con-
troller interprets these signals and then the computer and it’s program inside the controller
ON BOARD DIAGNOSTICS
The Central Command II control system utilizes a Diagnostic Code system that displays
diagnostic codes on the LCD display should a malfunction of the machine occur. The diag-
nostic code can be looked up in the diagnostic code chart and it will assist you in determin-
ing the cause of malfunction.
Содержание MINI-MAG SERIES
Страница 2: ......
Страница 12: ...Mini Mag Service Manual V1 0 TOC toc 1 6 TABLE OF CONTENTS BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 14: ...Mini Mag Service Manual V1 0 1 1 2 MAINTENANCE ...
Страница 15: ...Mini Mag Service Manual V1 0 1 1 3 MAINTENANCE ...
Страница 16: ...Mini Mag Service Manual V1 0 1 1 4 MAINTENANCE BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 22: ...Mini Mag Service Manual V1 0 2 2 6 MACHINE INTRODUCTION BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 28: ...Mini Mag Service Manual V1 0 3 3 6 SQUEEGEE SYSTEM SQUEEGEE ADJUSTMENT EXAMPLES ...
Страница 30: ...Mini Mag Service Manual V1 0 3 3 8 SQUEEGEE SYSTEM ...
Страница 42: ...Magnum Service Manual V1 0 6 6 4 SOLUTION SYSTEM BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 48: ...Mini Mag Service Manual V1 0 7 7 6 BRUSH DRIVE SYSTEM BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 54: ...Mini Mag Service Manual V1 0 8 8 6 BRUSH LIFT SYSTEM BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 56: ...Mini Mag Service Manual V1 0 9 9 2 TRACTION DRIVE SYSTEM BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 58: ...Mini Mag Service Manual V1 0 10 10 2 CHASSIS SYSTEM BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 78: ...Mini Mag Service Manual V1 0 12 12 12 ELECTRICAL SYSTEM BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...