background image

Estate Swing Summery of Functions 

The Estate Swing is only to be used for vehicular swing gates in a Class I  

setting. 

 

Class I: 

A vehicular gate opener (or system) intended for use in a home of 

one-to-four single family dwelling, or a garage or parking area associated 

therewith. 

 

The FAAC Estate Swing automated system was designed and built for controlling 

vehicle access. Do not use for any other purpose. 

 

The external automation with geared motor automates residential swing-leaf gates 

with leaves of up to 12’ in length, and is ideal for applications in which discretion 

is of great importance as it is a completely underground unit. It has the ability to 

be opened 180-degrees and works great with any type of gate mounting. The irre-

versible system ensures the gate is mechanical locked when the motor is not oper-

ating. A lock still needs be installed if security of high winds are a concern. A 

manual release makes it possible to move the gate in the event of a power-cut or 

fault.

 

 

 

 

Have this information on hand while handling all  

service and  warranty issues. 

This manual and its contents are produced by Web Direct Brands, Inc. and is based on the instructions  

written by FAAC,  

Содержание Estate Swing e-sU 2200 series

Страница 1: ...Manufactured by...

Страница 2: ...installation must conform to Standards EN 12453 and EN 12445 The safety level of the automated system must be C D 10 Before attempting any job on the system cut out electrical power and disconnect th...

Страница 3: ...h leaves of up to 12 in length and is ideal for applications in which discretion is of great importance as it is a completely underground unit It has the ability to be opened 180 degrees and works gre...

Страница 4: ...Setting the Gate 6 Installation of Operator 7 Power 8 Control Board Overview 9 10 LED Lights and Operational Displays 11 Programming Operating Parameters 12 Operating Parameters Chart 13 14 Programmi...

Страница 5: ...ax weight lbs Up to 1100 Operator overall dimensions LxHxD in See below approximate Operator Weight Foundation Box 27 lbs 32 lbs 1 Foundation Box 2 Bores for fastening cover 3 Operator 4 Support brack...

Страница 6: ...aves move smoothly without any irregular friction during entire travel Make sure the hinges are in good condition Ball bearing hinges are ideal for gates weighing over 200 lbs or over 10 in length Mak...

Страница 7: ...ided key Turn the key in the direction of the post as far as it will go 3 Pull the lever out 4 The gate should now be free of the operator lever To exit manual mode reverse the above steps Never lubri...

Страница 8: ...leaf around the axis of the top hinge see pic ture to right If you have a new gate to be installed fit the top hinge If possible use an adjust able hinge 2 Dig out a hole for the foundation box depend...

Страница 9: ...t is time to run PVC for power and drainage Lay down a PVC tube with a diameter of 1 38 This tube will be used for power and will lead to the control box Lay a second tube to drain off rain water from...

Страница 10: ...nit Every gate has different dimensions and require different guide brackets The axis of rotation for the opener should match the axis of rotation for the gate Meaning the center of the pivot in the f...

Страница 11: ...r must be as shown below The pinion must be on the opposite side of the leaves opening direction 4 Manually close the leaf and fit the driving levers supplied as seen below Use the appropriate lever f...

Страница 12: ...ransformer is not weather proof and must be kept in a covered area Plug covers are available from your dealer contact 1 800 640 GATE for a dealer in your area 5 Two 12V DC batteries may be run in seri...

Страница 13: ...put terminals for the optional backup batteries The battery power coming in must be 24V DC This can be achieved by running two 12V batteries in se ries During normal operation the unit keeps the batte...

Страница 14: ...lly closed contact This terminal is connected with the COMF through the limit switch When tripped connection opened it stops the motion of the second operator This terminal must be jumped with COMF FC...

Страница 15: ...pped FCA2 Motor 2 opening limit switch not tripped Motor 2 opening limit switch tripped STOP Stop command not activated Stop command activated FSW CL Closing safety device not tripped Closing safety d...

Страница 16: ...e appropriate lights are lit 2 The display should show 3 Press and hold down P2 until the display shows parameter A with the corresponding number that is currently default or pre viously programmed 4...

Страница 17: ...abled This parameter turns auto close on or off The pause time for the auto close is set during movement programming OPEN A Opens Closes Opens Opens Stops Closes Stops This parameter determines what a...

Страница 18: ...Switch Limit Switch LIMIT SWITCH This unit must be switched to L0 There is no limit switch option for this unit Single Leaf Gate Dual Leaf Gate SINGLE OR DUAL In this parameter you MUST specify wheth...

Страница 19: ...ld down P2 shows the A parameter and relevant number appear in the LED display 4 Give an OPEN A command This can be down with any opening device keypad push button etc wired into OPEN A and COM or usi...

Страница 20: ...is reached the gate s will stop 7 Wait for the amount of time you would like your gate s to pause for during normal operation before automatically re closing and then signal your opener using and OPEN...

Страница 21: ...impact and crushing Closing Safety Devices They operate only during the gate closing movement and therefore are suitable for pro tecting the closing zone against the risk of impact Opening Closing Sa...

Страница 22: ...es of the receiver board facing AWAY from the center of the Estate Swing board Setting the Dip Switches 1 Set the dip switches 1 12 on the receiver by switching them in the up or down position Record...

Страница 23: ...ops or reverses directions Check dip switches to the left of the LED display It should be 1 OFF 2 OFF 3 ON 4 On If the dip switches are wrong you must turn all power off before changing the dipswitche...

Страница 24: ...ions before the stops during normal operation If arms can t extend full expected range check the setback 6 x 6 inch setback is the correct setback for a 110 degree opening If the opener arm has the ph...

Страница 25: ...r the gate opener to be active this cir cuit must be closed When a device opens this circuit it stops the motion of the gate operator This circuit is the main circuit for safety devices i e photo eyes...

Отзывы: