In this stage, your control board will memorize where your limits are (identified
by limit switches, positive stops or both) in both opening and closing phases. Also
if the auto-close feature is activated it will learn the user specified pause time.
1. Release the operator gears using the manual release process for page . Once released, manually
move the gate(s) half way between the open and close stop points.
2. Relock the operator gears at the
half way point through its cycle.
Verify your operator control
board is showing
on the LED
display.
3. Press and hold down
P2
shows the A parameter
and relevant number appear in the LED display.
4. Give an
OPEN A
command. This can be down with any opening device (keypad, push button,
etc…) wired into OPEN A and COM or using the transmitter. You can also briefly (one second
or less) jump OPEN A and COM with a wire. This will begin your gate in the
CLOSING DIRECTION and the LED
display will read “Pr”.
IMPORTANT:
If the gate(s) begin to open rather than close,
the gate(s) must be stopped with a reset pulse. You can either:
Touch the TWO pins of the JMP “RESET” using a screwdriver
OR
Disconnect all power (transformer and backup battery)
Then switch the wires leading into APM1-CHM1 (if Dual Operator APM2-CHM2 also) and then
begin programming again.
Example:
Single Leaf
Example:
Dual Leaf
!$