manualshive.com logo in svg
background image

Control Board LED Lights 

- The control board LED lights are located above their respec-

tive terminals that they represent. (With exception of ALIM, power supply light, which is located 

below the power terminals in the upper left corner.) The LED lights are a quick way of verifying 

necessary connections are made. Below is a chart of their interpretations. 

()*(#

+

*

LED 

ON 

OFF 

ALIM 

Powers supply by transformer 

Power supply by battery or no power 

FCC 1 

Motor 1 closing limit switch - not tripped  Motor 1 closing limit switch - tripped 

FCA 1 

Motor 1 opening limit switch - not tripped  Motor 1 opening limit switch - tripped 

FCC 2 

Motor 2 closing limit switch - not tripped  Motor 2 closing limit switch - tripped 

FCA2 

Motor 2 opening limit switch - not tripped  Motor 2 opening limit switch - tripped 

STOP 

Stop command - not activated 

Stop command - activated 

FSW CL  Closing safety device - not tripped 

Closing safety device - tripped 

FSW OP  Opening safety device - not tripped 

Opening safety device - tripped 

During idle for single gate openers, all should be on except FCC 2 and FCA 2. 

During idle for dual gate openers, all LED lights should be on. 

 

If not using safety devices , you must jump STOP, FSW CL and FSW OP to COM in order 

for the gate opener to function. 

Standard Operation Display 

This is when the gate opener is not in parameter setting 

mode or programming mode. LED displays DS1 and DS2 will show the following: 

Gate Status 

Gate At Rest in Closed Position 

Gate Opening or Gate Open when Auto Close is OFF 

Gate open in pause status 

(Only with automatic re-close enabled - Parameter c) 

Gate Closing 

!!

Содержание Estate Swing e-sU 2200 series

Страница 1: ...Manufactured by...

Страница 2: ...installation must conform to Standards EN 12453 and EN 12445 The safety level of the automated system must be C D 10 Before attempting any job on the system cut out electrical power and disconnect th...

Страница 3: ...h leaves of up to 12 in length and is ideal for applications in which discretion is of great importance as it is a completely underground unit It has the ability to be opened 180 degrees and works gre...

Страница 4: ...Setting the Gate 6 Installation of Operator 7 Power 8 Control Board Overview 9 10 LED Lights and Operational Displays 11 Programming Operating Parameters 12 Operating Parameters Chart 13 14 Programmi...

Страница 5: ...ax weight lbs Up to 1100 Operator overall dimensions LxHxD in See below approximate Operator Weight Foundation Box 27 lbs 32 lbs 1 Foundation Box 2 Bores for fastening cover 3 Operator 4 Support brack...

Страница 6: ...aves move smoothly without any irregular friction during entire travel Make sure the hinges are in good condition Ball bearing hinges are ideal for gates weighing over 200 lbs or over 10 in length Mak...

Страница 7: ...ided key Turn the key in the direction of the post as far as it will go 3 Pull the lever out 4 The gate should now be free of the operator lever To exit manual mode reverse the above steps Never lubri...

Страница 8: ...leaf around the axis of the top hinge see pic ture to right If you have a new gate to be installed fit the top hinge If possible use an adjust able hinge 2 Dig out a hole for the foundation box depend...

Страница 9: ...t is time to run PVC for power and drainage Lay down a PVC tube with a diameter of 1 38 This tube will be used for power and will lead to the control box Lay a second tube to drain off rain water from...

Страница 10: ...nit Every gate has different dimensions and require different guide brackets The axis of rotation for the opener should match the axis of rotation for the gate Meaning the center of the pivot in the f...

Страница 11: ...r must be as shown below The pinion must be on the opposite side of the leaves opening direction 4 Manually close the leaf and fit the driving levers supplied as seen below Use the appropriate lever f...

Страница 12: ...ransformer is not weather proof and must be kept in a covered area Plug covers are available from your dealer contact 1 800 640 GATE for a dealer in your area 5 Two 12V DC batteries may be run in seri...

Страница 13: ...put terminals for the optional backup batteries The battery power coming in must be 24V DC This can be achieved by running two 12V batteries in se ries During normal operation the unit keeps the batte...

Страница 14: ...lly closed contact This terminal is connected with the COMF through the limit switch When tripped connection opened it stops the motion of the second operator This terminal must be jumped with COMF FC...

Страница 15: ...pped FCA2 Motor 2 opening limit switch not tripped Motor 2 opening limit switch tripped STOP Stop command not activated Stop command activated FSW CL Closing safety device not tripped Closing safety d...

Страница 16: ...e appropriate lights are lit 2 The display should show 3 Press and hold down P2 until the display shows parameter A with the corresponding number that is currently default or pre viously programmed 4...

Страница 17: ...abled This parameter turns auto close on or off The pause time for the auto close is set during movement programming OPEN A Opens Closes Opens Opens Stops Closes Stops This parameter determines what a...

Страница 18: ...Switch Limit Switch LIMIT SWITCH This unit must be switched to L0 There is no limit switch option for this unit Single Leaf Gate Dual Leaf Gate SINGLE OR DUAL In this parameter you MUST specify wheth...

Страница 19: ...ld down P2 shows the A parameter and relevant number appear in the LED display 4 Give an OPEN A command This can be down with any opening device keypad push button etc wired into OPEN A and COM or usi...

Страница 20: ...is reached the gate s will stop 7 Wait for the amount of time you would like your gate s to pause for during normal operation before automatically re closing and then signal your opener using and OPEN...

Страница 21: ...impact and crushing Closing Safety Devices They operate only during the gate closing movement and therefore are suitable for pro tecting the closing zone against the risk of impact Opening Closing Sa...

Страница 22: ...es of the receiver board facing AWAY from the center of the Estate Swing board Setting the Dip Switches 1 Set the dip switches 1 12 on the receiver by switching them in the up or down position Record...

Страница 23: ...ops or reverses directions Check dip switches to the left of the LED display It should be 1 OFF 2 OFF 3 ON 4 On If the dip switches are wrong you must turn all power off before changing the dipswitche...

Страница 24: ...ions before the stops during normal operation If arms can t extend full expected range check the setback 6 x 6 inch setback is the correct setback for a 110 degree opening If the opener arm has the ph...

Страница 25: ...r the gate opener to be active this cir cuit must be closed When a device opens this circuit it stops the motion of the gate operator This circuit is the main circuit for safety devices i e photo eyes...

Отзывы: