E145S 30
532369 - Rev.A
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
9
Status of the LEDs
LED
colour
meaning
OPEN A
red
Total motion command
active
not active
OPEN B
red
Partial motion command
active
not active
STOP
red
Stop command
not active
active
FSW CL
red
Closing photocell
not active
active
FSW OP
red
Opening photocell
not active
active
EDGE1
red
Opening sensitive edge
not active
active
EDGE2
red
Closing sensitive edge
not active
active
FCA1
red
Opening limit switch Leaf1
not engaged
engaged
FCC1
red
Closing limit switch Leaf1
not engaged
engaged
FCA2
red
Opening limit switch Leaf2
not engaged
engaged
FCC2
red
Closing limit switch Leaf2
not engaged
engaged
5V
blue
Power supply 5 V
on
off
24V
blue
Accessories power supply 24 V
"
on
off
ERROR
red
Error signalling
error
no errors
BUS
red
Bus 2easy devices
see § Bus 2easy devices
BUS MON green
Bus 2easy devices
USB
red
USB pen drive inserted (*)
Installed
not inserted
RADIO1
red
Channel 2 Omnidec (*)
active
not active
RADIO2
red
Channel 2 Omnidec (*)
active
not active
(*) Additional LED status or meanings are shown in the section on the accessory to which it refers.
10. DIAGNOSTICS
10.1 FIRMWARE VERSION
The firmware version is show on the display for 5
seconds each time it is switched on.
10.2 CHECKING THE MOVEMENT
Access basic programming and use function
M2
for
Leaf2 (displayed if the automation is configured for 2
leaves) and function
M1
for Leaf1.
1. The function displays
--
.
2. Use buttons
++
and
--
in dead man mode. One of
the expected commands must be given:
++
to OPEN (
oP
on the display)
--
to CLOSE (
cL
on the display)
Otherwise, temporarily disconnect the power supply
and invert the phases (OP/CL) of the motor.
10.3 AUTOMATED SYSTEM STATUS
The display, other than when in the programming
menu, provides information regarding the status of
the automation system (
).
8
Automated system status
00
CLOSED
01
OPEN
02
STATIONARY THEN OPENS
03
STATIONARY THEN CLOSES
04
IN PAUSE
05
OPENING
06
CLOSING
07
FAILSAFE IN PROGRESS
08
CHECK Bus 2easy
09
PREFLASHING BEFORE OPENING
10
PREFLASHING BEFORE CLOSING
11
EMERGENCY OPEN
12
EMERGENCY CLOSE
HP
HOLD POSITION
.
(flashing) SLEEP
10.4 LEDS CHECK
bold indicates the condition of the LEDs with the
board powered, the gate at its halfway position and no
connected device active (
=on ;
=off).