E145S 10
532369 - Rev.A
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
29 EDGE2
(Safety in closing devices active)
Connect a sensitive edge that, when activated during
closing, causes the gate to reverse.
This input can be configured by setting programming
function
Sc
to connect:
• sensitive edges with NC contact -default-
• resistive sensitive edges 8.2 kΩ
i
If the input is not used, bridge it with the
common contacts (-).
LIMIT SWITCHES
J6
LOCK
MAIN
LAMP
M1
M2
IN1 IN2 IN3 IN4 IN5
F
+
/R1
-
/R2
M
M
230V~
60W max
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22
27 28 29
23
24
25
26
RADIO
RP/DEC
2EASY
CONNECTIVITY
CR2032
USB-A
EDGE1
OUT1
CO
M
OP
CL
PE
N
L
CO
M
O
P-
A
+24V
+24V
-
-
-
-
OP
-B
ST
OP
FSW CL
FSW OP
OP
CL
OUT2
LOCK1 LOCK2
EDGE2
FCC2
FCA2
FCC1
FCA1
230V~
C
C
If no limit switches are used, there is no need to bridge
the inputs (NC). If at least one limit switch is used,
any unused contacts must be bridged with the com-
mon contacts (-).
23 FCA1
Opening limit switch motor 1 (NC)
24 FCC1
Closing limit switch motor 1 (NC)
25 FCA2
Opening limit switch motor 2 (NC)
26 FCC2
Closing limit switch motor 2 (NC)
To configure connections and functions, see § Ac-
cessories.
BUS 2EASY
DEVICES
LOCK
MAIN
LAMP
M1
M2
IN1 IN2 IN3 IN4 IN5
F
+
/R1
-
/R2
M
M
230V~
60W max
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22
27 28 29
23
24
25
26
RADIO
RP/DEC
2EASY
CONNECTIVITY
CR2032
USB-A
EDGE1
OUT1
CO
M
OP
CL
PE
N
L
CO
M
O
P-
A
+24V
+24V
-
-
-
-
OP
-B
ST
OP
FSW CL
FSW OP
OP
CL
OUT2
LOCK1 LOCK2
EDGE2
FCC2
FCA2
FCC1
FCA1
230V~
C
C
J10
i
If no BUS 2easy devices are used, leave the terminals
free.
For connecting and assigning addresses see § Ac-
cessories.
Do not exceed the maximum load of 500 mA.
ACCESSORIES POWER SUPPLY
J3
LOCK
MAIN
LAMP
M1
M2
IN1 IN2 IN3 IN4 IN5
F
+
/R1
-
/R2
M
M
230V~
60W max
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22
27 28 29
23
24
25
26
RADIO
RP/DEC
2EASY
CONNECTIVITY
CR2032
USB-A
EDGE1
OUT1
CO
M
OP
CL
PE
N
L
CO
M
O
P-
A
+24V
+24V
-
-
-
-
OP
-B
ST
OP
FSW CL
FSW OP
OP
CL
OUT2
LOCK1 LOCK2
EDGE2
FCC2
FCA2
FCC1
FCA1
230V~
C
C
500 mA max
The E145S supplies 24 V
"
and is short-circuit pro-
tected with a maximum current of 500 mA for con-
nected accessories.
14…16
-
Common contacts / Accessories power supply
negative
17 , 18
+24V
Accessories power supply positive
OUTPUTS
LOCK
MAIN
LAMP
M1
M2
IN1 IN2 IN3 IN4 IN5
F
+
/R1
-
/R2
M
M
230V~
60W max
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22
27 28 29
23
24
25
26
RADIO
RP/DEC
2EASY
CONNECTIVITY
CR2032
USB-A
EDGE1
OUT1
CO
M
OP
CL
PE
N
L
CO
M
O
P-
A
+24V
+24V
-
-
-
-
OP
-B
ST
OP
FSW CL
FSW OP
OP
CL
OUT2
LOCK1 LOCK2
EDGE2
FCC2
FCA2
FCC1
FCA1
230V~
C
C
J3
J12
100 mA max
The E145S has two Open Collector outputs that are ac-
tivated according to programming functions
o1
and
o2
.
OUT active
OUT not active
0 V
"
open circuit
Do not exceed the maximum load of 100 mA for each