E145S 14
532369 - Rev.A
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
2
BASIC programming menu
Function
default
C C
SIMPLY CONNECT
To enable Simply Connect, select a communica-
tion channel:
0
disabled
1
(CH1) ,
2
(CH2) ,
3
(CH3) ,
4
(CH4)
0
CF
TYPE OF AUTOMATION
1
swing gate
2
sliding gate
1
dF
DEFAULT CONFIGURATION
Displays
Y
if the programming corresponds to the
default settings. Select
Y
if you wish to reload
the default values for the type of automation.
Y
the programming corresponds to the
DEFAULT settings
no
the programming DOES NOT correspond to
the default settings
Y
Lo
FUNCTIONING LOGIC
E
Semi-automatic
EP
Semi-automatic step by step
S
Automatic Safety
SA
Automatic Safety 2
SP
Automatic Safety Step by Step
A1
Automatic 1
A
Automatic
AP
Automatic Step by Step
At
Automatic with Timer Function
b
Semi-automatic b
bC
Mixed (Impulse opening / Hold-to-run
closing)
C
Hold-to-run
E
PA
PAUSE TIME
(displayed only if an automatic logic has been
selected)
Displayed in seconds up to 59, then in steps of 10 s.
00
…
59
(Adjustment step: 1 s)
1.0
…
9.5
(Adjustment step: 10 s)
30
Pb
PARTIAL PAUSE TIME
(displayed only if an automatic logic has been
selected)
Carried out after partial opening.
Displayed in seconds up to 59, then in steps of 10 s.
00
…
59
(Adjustment step: 1 s)
1.0
…
9.5
(Adjustment step: 10 s)
30
Mn
NUMBER of MOTORS
connected
1
1 motor
2
2 motors
2
Function
default
F1
MOTOR 1 POWER
01
…
50
(levels;
50
=maximum power)
25
F2
MOTOR 2 POWER
(displayed only if
Mn
=
2
)
01
…
50
(levels;
50
=maximum power)
25
En
ENCODER
Enables/disables the encoder on both motors.
no
disabled
Y
enabled
no
FA
OPENING LIMIT SWITCH
(displayed only if
CF
=
1
)
Enables/disables the opening limit switches, to
stop the automation or start the slowdown. Mod-
ifying the value requires a new SETUP.
no
disabled
01
stop
02
start slowdown
no
FC
CLOSING LIMIT SWITCH
(displayed only if
CF
=
1
)
Enables/disables the closing limit switches, to stop
the automation or start the slowdown. Modifying
the value requires a new SETUP.
no
disabled
01
stop
02
start slowdown
no
So
INPUT EDGE1 CONFIGURATION
nc
Sensitive edge with NC contact
1r
1 Resistive sensitive edge 8.2 kΩ
2r
2 Resistive sensitive edges 8.2 kΩ (Con-
nected in parallel)
nc
Sc
INPUT EDGE2 CONFIGURATION
nc
Sensitive edge with NC contact
1r
1 Resistive sensitive edge 8.2 kΩ
2r
2 Resistive sensitive edges 8.2 kΩ (Con-
nected in parallel)
nc
Br
BRAKING FOR SLIDING GATE
(displayed only if
CF
=
2
)
00
braking disabled
01
…
10
(levels;
10
=maximum braking)
05
Cd
LEAF CLOSING DELAY
(
displayed only if
Mn
=
2
)
The delay is applied to MOTOR 1.
Displayed in seconds up to 59, then in steps of 10 s.
00
…
59
(Adjustment step: 1 s)
1.0
…
1.3
(Adjustment step: 10 s)
05