![FAAC E145S Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/faac/e145s/e145s_manual_3117244017.webp)
E145S 15
532369 - Rev.A
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
Function
default
bu
Learn BUS 2easy devices
See the relative section.
M2
MOTOR 2 OPERATION in dead man mode
(displayed only if
Mn
=
2
)
+
OPEN (displaying
oP
)
-
CLOSE (displaying
cL
)
--
M1
MOTOR 1 OPERATION in dead man mode
+
OPEN (displaying
oP
)
-
CLOSE (displaying
cL
)
--
tL
SETUP
See the relative section.
--
St
LEAVING THE PROGRAMMING MODE
Y
exit saving the settings
no
exit without saving the settings
After having confirmed using button
FF
, the display
indicates the STATUS of the automation:
Y
00
CLOSED
08
CHECK Bus 2easy
01
OPEN
09
PREFLASHING BEFORE OPEN-
ING
02
STATIONARY THEN OPENS
10
PREFLASHING BEFORE CLOS-
ING
03
STATIONARY THEN CLOSES
11
EMERGENCY OPEN
04
IN PAUSE
12
EMERGENCY CLOSE
05
OPENING
HP
HOLD POSITION
06
CLOSING
.
(flashing) SLEEP
07
FAILSAFE IN PROGRESS
3
ADVANCED programming menu
Function
default
bO
MAXIMUM TORQUE AT INITIAL THRUST
When it starts, the motor operates at maximum
power for the time set in this option.
01
…
10
(Adjustment step: 1 s)
01
cS
CLOSING THRUST
(not
displayed if
FC
=
1
)
This function assists the closing of the electric lock:
it pushes against the closing stop with maximum
force for 2 s. DO NOT enable the function if there
is not a mechanical closing stop fitted.
no
disabled
Y
enabled
no
rS
REVERSE STROKE FOR OPENING
(not
displayed if
FC
=
1
)
This function assists the release of the electric
lock: it pushes against the closing stop before
opening. DO NOT enable the function if there
is not a mechanical closing stop fitted.
no
disabled
Y
enabled
no
Od
LEAF OPENING DELAY
(displayed only if
Mn
=
2
)
The delay is applied to MOTOR 2.
Displayed in seconds up to 59, then in steps of 10 s.
00
…
59
(Adjustment step: 1 s)
1.0
…
1.3
(Adjustment step: 10 s)
02
IP
REVERSE ON OBSTACLE
This function specifies the amount the leaf is
reversed after an obstacle has been detected.
no
total reverse
Y
partial reverse (2 s)
no
r1
SLOWDOWN LEAF 1
(NOT displayed if
FA
/
FC
=
2
)
Specifies the deceleration space for the leaf con-
nected to MOTOR 1 (% of the total length of travel).
01
…
50
(Adjustment step: 1%)
20
r2
SLOWDOWN LEAF 2
(NOT displayed if
FA
/
FC
=
2
, or if
Mn
=
1
)
Specifies the deceleration space for the leaf con-
nected to MOTOR 2 (% of the total length of travel).
01
…
50
(Adjustment step: 1%)
20