![FAAC E145S Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/faac/e145s/e145s_manual_3117244020.webp)
E145S 18
532369 - Rev.A
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
OPEN during pause, causes it to close.
OPEN during opening or closing, stops it and the
next OPEN command reverses the direction.
The triggering of the closing photocells: during
pause, closes the gate - during opening, requests
closing - during closing, causes the gate to open and
then closes it immediately.
■
A1
AUTOMATIC1
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during opening, is ignored.
OPEN during the pause, resets the pause time.
OPEN during closing, causes it to reopen.
The triggering of the closing photocells: during
pause, closes the gate - during opening, requests
closing - during closing, causes the gate to reverse
and then closes it immediately.
■
A
AUTOMATIC
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during the pause, resets the pause time.
OPEN during opening, is ignored.
OPEN during closing, causes it to reopen.
The triggering of the closing photocells: during pause,
reloads the pause time.
■
AP
AUTOMATIC STEP-BY-STEP
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during pause, stops the gate and the next
OPEN command closes it.
OPEN during opening, stops the gate and the next
OPEN command closes it.
OPEN during closing, causes it to reopen.
The triggering of the closing photocells: during pause,
reloads the pause time.
■
At
AUTOMATIC TIMER
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed. If an OPEN input is active at
power up, it opens, otherwise it closes.
OPEN during the pause, resets the pause time.
OPEN during opening, is ignored.
OPEN during closing, causes it to reopen.
The triggering of the closing photocells: during pause,
reloads the pause time.
■
b
SEMI-AUTOMATIC b
This logic uses the OPEN A commands to open and OPEN B (CLOSE)
to close. Partial motion is not available.
OPEN if the automation is closed, causes it to open.
OPEN during closing, causes it to reopen.
If the photocells are triggered: the direction of move-
ment is reversed.
■
bC
MIXED (b during opening, C during closing)
This logic uses the OPEN A (OPEN) impulse command to open, and
maintained OPEN B (CLOSE) to close. Partial motion is not available.
!
A maintained command must be activated intention-
ally and the automation must be visible.
OPEN opens the automation.
CLOSE maintained, closes the automation (when
opening, a non-maintained CLOSE command stops it).
OPEN during closing, causes it to reopen.
The triggering of the closing photocells reverses the
direction of movement, the triggering of the opening
photocells stops the movement.
■
C
DEAD-MAN
This logic uses the maintained commands OPEN A (OPEN) to open
and OPEN B (CLOSE) to close. Partial motion is not available.
!
A maintained command must be activated intention-
ally and the automation must be visible.
Maintained OPEN opens the automation.
Maintained CLOSE closes the automation.
If the photocells are triggered: movement is stopped.
Содержание E145S