6. SET-UP
RISKS
PERSONAL PROTECTIVE EQUIPMENT
Carry out following (§ specific sections).
1. Turn power on to the board.
2. Check that the status of the LEDs is correct.
3. Configure the type of automation (Basic pro-
gramming,
cF
) and the number of motors (Basic
programming,
Mn
).
4. Enable the encoders, if present (Basic program-
ming,
En
) and the limit switches (Basic program-
ming,
FA
,
FC
).
5. Check the leaf movement (Basic programming,
M2
,
M1
).
6. Carry out the SETUP procedure that includes the
registration of BUS 2easy that are connected (Basic
programming,
tL
).
7. Memorise the radio controls, if used.
8. Complete the required programming.
9. Carry out the final checks to make sure that the
automation system is working correctly with all
the devices installed.
6.1 TURN POWER ON TO THE BOARD
Turn on the mains power supply; the 5 V and 24 V LEDs
come on and the following appears on the display:
bo
, then the FW version (e.g.
4.0
), then
S0
(SETUP
required).
If the SETUP has already been carried out
bo
, appears
on the display and then the automation status (e.g.
00
)
For LED and display signals see § Diagnostics.
6.2 PROGRAMMING
LOCK
MAIN
LAMP
M1
M2
IN1 IN2 IN3 IN4 IN5
F
+
/R1
-
/R2
M
M
230V~
60W max
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22
27 28 29
23
24
25
26
RADIO
RP/DEC
2EASY
CONNECTIVITY
CR2032
USB-A
EDGE1
OUT1
CO
M
OP
CL
PE
N
L
CO
M
O
P-
A
+24V
+24V
-
-
-
-
OP
-B
ST
OP
FSW CL
FSW OP
OP
CL
OUT2
LOCK1 LOCK2
EDGE2
FCC2
FCA2
FCC1
FCA1
230V~
C
C
When the display shows the automation status, you
can enter basic or advanced programming mode.
■
Basic programming
1. Press and hold the
FF
button:
The first function (
C C
) appears on the display,
which is displayed as long as button F remains
pressed.
2. Release the button: the display shows the value
of the function.
3. Press the
++
or
--
button to modify, then press the
FF
button to confirm to go to the next function.
Proceed in the same way for all the functions.
■
Advanced programming
1. Press and hold down the
FF
button, then the
++
button as well:
The first function (
bo
) appears on the display,
which is displayed as long as button F remains
pressed.
2. Release the buttons: the display shows the value
of the function.
3. Press the
++
or
--
button to modify, then press the
FF
button to confirm to go to the next function.
Proceed in the same way for all the functions.
■
Exiting programming mode
i
Every modified value becomes effective immediately,
but when exiting from programming mode you have
to decide whether to save the modifications or not.
Modifications are lost if no buttons have been pressed
for 10 minutes or if power to the board is disconnected
before they have been saved.
1. Press and hold down the
FF
button, then the
+
+
button as well.
Alternatively, scroll through the programming
menu until you reach the last function (
St
).
2. Select:
Y
= save the changes
no
= DO NOT save the changes
3. Press button
FF
to confirm: the display reverts to
the automation status view.