![FAAC E145S Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/faac/e145s/e145s_manual_3117244019.webp)
E145S 17
532369 - Rev.A
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
Function
default
nc
THOUSANDS OF CYCLES
Displays the thousands of cycles that have been
performed
.
To reset the cycle counter: press
++
and
--
for 5 s
00
…
65
(programmable if
AS
=
Y
)
00
nd
TENS OF CYCLES
Displays the tens of cycles that have been per-
formed
.
00
…
53
(if
AS
=
no
)
00
…
65
(programmable if
AS
=
Y
)
00
St
LEAVING THE PROGRAMMING MODE
Y
exit saving the settings
no
exit without saving the settings
After having confirmed using button
FF
, the display
indicates the STATUS of the automation:
Y
00
CLOSED
08
CHECK Bus 2easy
01
OPEN
09
PREFLASHING BEFORE OPEN-
ING
02
STATIONARY THEN OPENS
10
PREFLASHING BEFORE CLOS-
ING
03
STATIONARY THEN CLOSES
11
EMERGENCY OPEN
04
IN PAUSE
12
EMERGENCY CLOSE
05
OPENING
HP
HOLD POSITION
06
CLOSING
.
(flashing) SLEEP
07
FAILSAFE IN PROGRESS
6.3 OPERATING LOGICS
i
the STOP command has priority in all the logics and
stops the automation.
The CLOSE command always closes the automation.
■
E
SEMI-AUTOMATIC
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to open.
OPEN if the automation is open, causes it to close.
OPEN during opening, stops the gate and the next
OPEN command closes it.
OPEN during closing, causes it to reopen.
The triggering of the photocells: during movement,
reverses the gate.
■
EP
SEMI-AUTOMATIC STEP-BY-STEP
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to open.
OPEN if the automation is open, causes it to close.
OPEN during opening or closing, stops the gate and
the next OPEN command reverses the direction.
The triggering of the photocells: during movement,
reverses the gate.
■
S
AUTOMATIC SAFETY
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during opening, causes it to close.
OPEN during pause, causes it to close.
OPEN during closing, causes it to reopen.
The triggering of the closing photocells: during
pause, closes the gate - during opening, requests
closing - during closing, causes the gate to reverse
and then closes it immediately.
■
SA
AUTOMATIC SAFETY 2
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during opening, is ignored.
OPEN during pause, causes it to close.
OPEN during closing, causes it to reopen.
The triggering of the closing photocells: during pause,
reloads the pause time.
■
SP
AUTOMATIC STEP BY STEP
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
Содержание E145S