E024S 

     7 

         732642 - Rev. F

 3 

TECHNICAL SPECIFICATIONS 

Power supply voltage 

*

230V~ (+6% -10%) - 50Hz

or

115V~ (+6% -10%) - 60Hz

Absorbed power

4W

Motor max. load

150W x 2

Accessories max. current 
(+24V=)

250 mA

BUS Accessories max.current

400 mA

Operating ambient tempera-
ture

-20°C... +55°C

Fuses 

*

F1 = self-resetting;

F2 = T2A-250V~ 

or

 T4A-

120V~

Function logics

A, E, AP, EP,A1,B,C

Work time (time-out)

5 minutes (fixed)

Pause time

Varies according to learning

(max. 10 min.)

Terminal board inputs

Open A, Open B, Stop, BUS 

(I/O)

Connector inputs

Power supply, battery

module XF 433 or XF 868

Terminal board outputs

Motors, flashing lamp, power 

supply to accessories, elec

-

tric lock, service light contact 

(90 sec fixed)

Programmable functions

 Speed (High - Low)

Learning functions

Pause time,

leaf closing delay

Integrated radio channels 
type

DS, SLH (max 250 channels)

LC -RC (max 250 channels ) 

J1

POWER SUPPLY connector 

J2

SERVICE LIGHT command terminal-board

J3

FLASHING LAMP terminal-board

J4

ELECTRIC LOCK terminal-board

J5

COMMANDS terminal-board 

J7

MOTOR 1 terminal-board

J8

MOTOR 2 terminal-board

J9

Rapid connection for XF MODULE

J10

BUS terminal-board

J11

BATTERY connector

SW1

SET UP push-button

SW2

SPEED push-button

SW3

LOGIC push-button

DS1

Programming Dip-switch

F1

Accessories protective fuse

F2

Fuses protecting transformers and motors

LED

Signalling LEDs

3.1 

DESCRIPTION OF COMPONENTS

Terminal  and/or 

terminal-board

Description

Device connected

1

J5

+24V=

Power supply for 

accessories

2

GND

Negative

3

STOP

Device with NC 

contact which 

causes the 

automated system 

to shut down

4

OPEN B

Device with N.O 

contact

5

OPEN A

J10

RED terminal

BUS

Safety devices with 

BUS technology

J2

GREY terminal

SERVICE LIGHT

(on for 90 sec. 

following 

movement)

Service Light control 

output (connect a 

relay coil at 24V= 

/100mA max)

J3

ORANGE terminal

LAMP

Flashing lamp 

24V= / 15W

J4

BLUE terminal

LOCK

Electric lock 12V~ 

or 24 V= (to be 

installed on leaf 1)

J7

MOT1

Motor 1 (leaf 1)

J8

MOT2

Motor 2 (leaf 2)

3.2 

DESCRIPTION OF TERMINAL-BOARDS

 5 

PROGRAMMING THE SPEED

The function SPEED can be adjusted at any time by pressing 
push-button SW2.
The selected speed is then displayed on LED LD8:
 

LED on  = HIGH speed

 

LED off  = LOW speed 

 Leaf 1 means the leaf which opens first during 

the opening operation.

 The service light control is active during the 

entire gate opening or closing movement and 

for the successive 90 seconds.

*

 The power supply and the fuse are related to the purchased 

version.

 

The self-resetting fuse F1 stops the power supply to the 

accessories by opening a circuit if a current over 500 mA is 
detected. It automatically resets after 5 seconds.

3.3 

ANTI-CRUSHING FUNCTION

The electronic anti-crushing function is obtained by controlling 
the  current  consumption  or  the  encoder  of  the  motors 
connected to the E024S unit.
If the gate detects an obstacle during the opening or closing 
movement, the anti-crushing function activates and reverses 
the sense of direction of the operator, thus increasing the safety 
degree of the automated system.

 4 

PROGRAMMING THE LOGIC 

Repeatedly press the SW3 LOGIC push-button to select one of 
the 7 programming logics available.
The selected logic is signaled by the LD7 LED: the number of 
flashings corresponds to the number of the selected logic.

See paragraph 6.3.3.

ENGLISH

Содержание E024S

Страница 1: ...E024S...

Страница 2: ...ETUPS MUSS MIT DEN DIP SWITCHES DS1 DS3 DS4 DER AN DIE ANLAGE E024S ANGESCHLOSSENE ANTRIEB ANGEW HLT WERDEN ANLEITUNGEN BER ALLE ANDEREN EINSTELLUNGEN SIND DER BETRIEBSANLEITUNG E024S ZU ENTNEHMEN ATE...

Страница 3: ...Bologna 10 11 2014 CEO A Marcellan INDEX BOX LAYOUT 4 1 WARNINGS E024S 5 2 LAYOUT AND CONNECTIONS E024S 5 1 WARNINGS E024S FITTED ON 391 6 2 LAYOUT AND CONNECTIONS E024S FITTED ON 391 6 3 TECHNICAL SP...

Страница 4: ...e box are shown in Fig A The cover hinges can be moved upward to allow opening the box housing Fig C they can also be removed and re posi tioned in order to enable the cover to open to the right or le...

Страница 5: ...rate power cables from control and safety cables push button receiver photocells etc To avoid any electrical disturbance use separate sheaths or a shielded cable with the shield earthed CONTROL UNIT E...

Страница 6: ...wer cables from control and safety cables push button receiver photocells etc To avoid any electrical disturbance use separate sheaths or a shielded cable with the shield earthed CONTROL UNIT E024S fi...

Страница 7: ...o shut down 4 OPEN B Device with N O contact 5 OPEN A J10 RED terminal BUS Safety devices with BUS technology J2 GREY terminal SERVICE LIGHT on for 90 sec following movement Service Light control outp...

Страница 8: ...utomatically During the Setup phase both LEDs flash The leaves start to open one at a time from any position till they detect the opening limit stop Next the leaves start to close one at a time till t...

Страница 9: ...t stop is detected it is set as leaf 1 closing stop point if an open command is detected it is set as leaf 1 closing stop point If the SETUP procedure is performed correctly the LD4 and LD5 LEDs turn...

Страница 10: ...push button is released both LD4 and LD5 LEDs flash 6 The default configuration is reset and the new Setup can be started Fig 2 6 3 6 PARAMETER DEFINITION Anti wind the anti wind function enables the...

Страница 11: ...memory store total opening OPEN A or partial opening OPEN B and by holding it down press the push button SETUP SW1 6 The LED on the board lights up on steady beam for 1 second and then goes OFF indic...

Страница 12: ...ing OPEN B and as you hold it down also press the SETUP SW1 push button The relevant LED starts to flash slowly for 5 sec 3 Release both push buttons Within these 5 sec press the appropriate push butt...

Страница 13: ...e recognised during bus device acquisition chapter 7 2 The use of this type of encoder offers precise and constant information on leaf position guaranteeing reverse movement in case of obstacles The e...

Страница 14: ...orrect coupling of the encoder with the leaf as indicated in the following figure LED ON FLASHING OFF DL 1 Power supply on and BUS connected to board Power supply on but BUS not connected No power sup...

Страница 15: ...The closing photocells reapply the pause E Semiautomatic an OPEN pulse opens the gate and the following one closes it An OPEN pulse stops the gate when opening and reopens when the gate is closing The...

Страница 16: ...at release OPEN stops saves CLOSE OPEN recloses leaves immediately 1 recloses leaves immediately no effect OPEN CLOSE disabled no effect no effect CLOSE disabled no effect OPEN CLOSE disa bled CLOSIN...

Страница 17: ...loses after 5 s stops and opens at release saves CLOSE OPEN IN PAUSE recharges pause time 1 recharges pause time 1 stops operation no effect stops and closes on release after 5 s recharges pause time...