E024S

ATTENZIONE

PRIMA DI EFFETTUARE IL SETUP SELEZIONARE 
CON I DIP SWITCH DS1(DS3-DS4) L’OPERATORE 
COLLEGATO ALL’APPARECCHIATURA E024S.
PER TUTTI GLI ALTRI SETTAGGI FARE RIFERIMENTO 
AL MANUALE ISTRUZIONI E024S.

ATTENTION

BEFORE PERFORMING THE SETUP, SELECT 
THE OPERATOR CONNECTED TO THE E024S 
EQUIPMENT WITH THE DS1(DS3-DS4) DIP 
SWITCHES.
FOR ALL OTHER SETTINGS, REFER TO THE E024S 
INSTRUCTION MANUAL.

ATTENTION

AVANT D'EFFECTUER LE SETUP, SÉLECTIONNER 
L'OPÉRATEUR CONNECTÉ À L'ÉQUIPEMENT E024S 
À L'AIDE DES DIP SWITCH DS1(DS3-DS4).
POUR TOUTES LES AUTRES OPÉRATIONS DE SETUP, 
REPORTEZ-VOUS AU MANUEL D'INSTRUCTIONS 
E024S.

ACHTUNG

VOR DER DURCHFÜHRUNG EINES SETUPS MUSS 

MIT DEN DIP-SWITCHES  DS1(DS3-DS4) DER AN 

DIE ANLAGE E024S ANGESCHLOSSENE ANTRIEB 

ANGEWÄHLT WERDEN.

ANLEITUNGEN ÜBER ALLE ANDEREN 

EINSTELLUNGEN SIND DER BETRIEBSANLEITUNG 

E024S ZU ENTNEHMEN.

ATENCIÓN

ANTES DE EFECTUAR EL SETUP SELECCIONAR 
CON LOS DIP SWITCHES DS1 (DS3-DS4) EL 
OPERADOR CONECTADO AL EQUIPO E024S.
PARA TODAS LAS OTRAS CONFIGURACIONES 
TOMAR COMO REFERENCIA EL MANUAL DE 
INSTRUCCIONES E024S.

LET OP

ALVORENS DE SETUP UIT TE VOEREN, MOET 
MET DE DIPSCHAKELAARS (DS3-DS4) DE 
AANDRIJVING WORDEN GESELECTEERD DIE 
OP HET APPARAAT E024S IS AANGESLOTEN.
RAADPLEEG VOOR ALLE ANDERE INSTELLINGEN 
DE INSTRUCTIEHANDLEIDING E024S.

DS4

DS3 DS2 DS1

Description

OFF

OFF

391

ON

OFF

S418

OFF

ON

412-413-415-390-770

ON

ON

HYDRAULIC MOTOR

S450H/S700H/S800H/S800H ENC

OFF OFF

LOW FORCE

ON OFF

MEDIUM - LOW FORCE

OFF ON

MEDIUM - HIGH FORCE

ON

ON

HIGH FORCE  

Содержание E024S

Страница 1: ...E024S...

Страница 2: ...ETUPS MUSS MIT DEN DIP SWITCHES DS1 DS3 DS4 DER AN DIE ANLAGE E024S ANGESCHLOSSENE ANTRIEB ANGEW HLT WERDEN ANLEITUNGEN BER ALLE ANDEREN EINSTELLUNGEN SIND DER BETRIEBSANLEITUNG E024S ZU ENTNEHMEN ATE...

Страница 3: ...Bologna 10 11 2014 CEO A Marcellan INDEX BOX LAYOUT 4 1 WARNINGS E024S 5 2 LAYOUT AND CONNECTIONS E024S 5 1 WARNINGS E024S FITTED ON 391 6 2 LAYOUT AND CONNECTIONS E024S FITTED ON 391 6 3 TECHNICAL SP...

Страница 4: ...e box are shown in Fig A The cover hinges can be moved upward to allow opening the box housing Fig C they can also be removed and re posi tioned in order to enable the cover to open to the right or le...

Страница 5: ...rate power cables from control and safety cables push button receiver photocells etc To avoid any electrical disturbance use separate sheaths or a shielded cable with the shield earthed CONTROL UNIT E...

Страница 6: ...wer cables from control and safety cables push button receiver photocells etc To avoid any electrical disturbance use separate sheaths or a shielded cable with the shield earthed CONTROL UNIT E024S fi...

Страница 7: ...o shut down 4 OPEN B Device with N O contact 5 OPEN A J10 RED terminal BUS Safety devices with BUS technology J2 GREY terminal SERVICE LIGHT on for 90 sec following movement Service Light control outp...

Страница 8: ...utomatically During the Setup phase both LEDs flash The leaves start to open one at a time from any position till they detect the opening limit stop Next the leaves start to close one at a time till t...

Страница 9: ...t stop is detected it is set as leaf 1 closing stop point if an open command is detected it is set as leaf 1 closing stop point If the SETUP procedure is performed correctly the LD4 and LD5 LEDs turn...

Страница 10: ...push button is released both LD4 and LD5 LEDs flash 6 The default configuration is reset and the new Setup can be started Fig 2 6 3 6 PARAMETER DEFINITION Anti wind the anti wind function enables the...

Страница 11: ...memory store total opening OPEN A or partial opening OPEN B and by holding it down press the push button SETUP SW1 6 The LED on the board lights up on steady beam for 1 second and then goes OFF indic...

Страница 12: ...ing OPEN B and as you hold it down also press the SETUP SW1 push button The relevant LED starts to flash slowly for 5 sec 3 Release both push buttons Within these 5 sec press the appropriate push butt...

Страница 13: ...e recognised during bus device acquisition chapter 7 2 The use of this type of encoder offers precise and constant information on leaf position guaranteeing reverse movement in case of obstacles The e...

Страница 14: ...orrect coupling of the encoder with the leaf as indicated in the following figure LED ON FLASHING OFF DL 1 Power supply on and BUS connected to board Power supply on but BUS not connected No power sup...

Страница 15: ...The closing photocells reapply the pause E Semiautomatic an OPEN pulse opens the gate and the following one closes it An OPEN pulse stops the gate when opening and reopens when the gate is closing The...

Страница 16: ...at release OPEN stops saves CLOSE OPEN recloses leaves immediately 1 recloses leaves immediately no effect OPEN CLOSE disabled no effect no effect CLOSE disabled no effect OPEN CLOSE disa bled CLOSIN...

Страница 17: ...loses after 5 s stops and opens at release saves CLOSE OPEN IN PAUSE recharges pause time 1 recharges pause time 1 stops operation no effect stops and closes on release after 5 s recharges pause time...

Страница 18: ...79 6645 faactm info faacgroup com www faac de INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com IRELAND NATIONAL AUTOMATION LIMITED Boyle Co Roscommon Ireland tel 35...

Отзывы: