![FAAC E024S Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/faac/e024s/e024s_user-manual_3111954015.webp)
E024S
15
732642 - Rev. F
LOGIC “A”
PULSES
AUTOMATED SYSTEM STATUS
OPEN A
OPEN B
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and closes
after pause time
opens released
leaf and closes
after pause time
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
no effect (1)
no effect
stops operation
reverses at
closure
no effect
stops and opens at
release (saves CLOSE)
OPEN IN PAUSE
recharges
pause time (1)
recharges
pause time of
released leaf
stops operation
no effect
recharges
pause time
(CLOSE disabled)
recharges
pause time
(CLOSE disabled)
CLOSING
reopens leaves
immediately
reopens leaves
immediately
stops operation
no effect
reverses at opening stops and opens at
release (saves CLOSE)
BLOCKED
closes leaves
closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE disa
-
bled)
(1) if the cycle began with OPEN-B (released leaf), both leaves are activated at opening
12
FUNCTION LOGICS
LOGIC
Automation status:
stopped
Automation status:
moving
Status:
triggered photocell
A
Automatic
an OPEN pulse opens the gate
and closes automatically after the
pause time
An OPEN pulse is ignored when the
gate opens, is reapplied during
the pause and reopens when the
gate closes
The closing photocells reapply the
pause
E
Semiautomatic
an OPEN pulse opens the gate
and the following one closes it
An OPEN pulse stops the gate
when opening and reopens when
the gate is closing
The photocells invert during motion
EP
Semi-automatic, Step-by-
Step
an OPEN pulse opens the gate
and the following one closes it
An OPEN pulse blocks during
motion
The photocells invert during motion
A1
Automatic 1
an OPEN pulse opens the gate
and closes automatically after the
pause time
An OPEN pulse is ignored when the
gate opens, is reapplied during
the pause and reopens when the
gate closes
The closing photocells close the
gate once again during the pau
-
se; they memorise closure when
the gate opens and immediately
invert when closing
AP
Automatic, Step-by-Step
an OPEN pulse opens the gate
and closes automatically after the
pause time
An OPEN pulse blocks when the
gate opens and during the pause
and inverts when it closes
The closing photocells reapply the
pause
b
Semi-automatic “b” (OPEN-B
inputs become CLOSE)
logic with two separate com
-
mands: OPEN-A pulse opens;
CLOSE pulse closes
An OPEN-A pulse opens when
the gate closes, a CLOSE pulse
closes when it opens
The photocells invert during
motion
C
Dead-man (OPEN-B inputs
become CLOSE)
logic with two separate com
-
mands: pressed OPEN-A opens;
pressed CLOSE closes
An OPEN-A pulse opens when
the gate closes; a CLOSE pulse
closes when it opens
The photocells invert during
motion
ENGLISH
Содержание E024S
Страница 1: ...E024S...