1)  ATTENTION! To ensure the safety of people, it is important that you read 

all the following instructions. Incorrect installation or  incorrect use of the 

product  could  cause  serious harm   to people.

  2)  Carefully read the instructions before beginning to install the product.
  3)  Do not  leave packing materials (plastic, polystyrene, etc.)   within  reach 

of  children as  such materials  are  potential  sources  of  danger.

  4)  Store these instructions for  future reference.
  5)  This product was designed and built strictly for the use indicated in this 

documentation.  Any  other  use,  not  expressly  indicated  here,  could 

compromise the good condition/operation of the product and/or be 

a source of danger.

  6)  FAAC declines all liability caused by improper use or use other than 

that for which the automated system was intended.

  7)  Do not install the equipment in an explosive atmosphere: the presence 

of  inflammable gas or fumes is a serious danger to safety.

  8)  The mechanical parts must conform to the provisions of Standards EN 

12604 and EN 12605.

 

  For  non-EU  countries,  to  obtain  an  adequate  level  of  safety,  the 

Standards mentioned above must be observed, in addition to national 

legal regulations.

  9)  FAAC  is  not  responsible  for  failure  to  observe  Good  Technique  in 

the construction of the closing elements to be motorised, or for any 

deformation that may occur during use.

 10)  The installation must conform to Standards EN 12453 and EN 12445.

 

    For  non-EU  countries,  to  obtain  an  adequate  level  of  safety,  the 

Standards mentioned above must be observed, in addition to national 

legal regulations.

 11)  Before attempting any job on the system, cut out electrical power .
 12)  The mains power  supply of the automated system must be fitted with 

an all-pole  switch with contact opening distance of 3mm or greater. Use 

of a 6A thermal breaker with all-pole circuit break is recommended.

 13)  Make  sure  that  a  differential  switch  with  threshold  of  0.03  A  is  fitted 

upstream of the system.

 14)  Make sure that the earthing system is perfectly constructed, and connect 

metal parts of  the means of  the closure to it. 

 15)  The  safety  devices  (EN  12978  standard)    protect  any  danger  areas 

against 

mechanical movement Risks

, such as crushing, dragging, and 

shearing.

 16)  Use of at least one indicator-light (e.g. FAACLIGHT ) is recommended 

for every system, as well as a warning sign adequately secured to the 

frame structure, in addition to the devices mentioned at point “15”.

 17)  FAAC declines all liability as concerns safety and efficient operation of 

the automated system, if system components not produced by FAAC 

are used.

18)   For maintenance, strictly use original parts by FAAC.
 19)  Do  not  in  any  way  modify  the  components  of  the  automated 

system.

 20)  The installer shall supply all information concerning manual operation 

of the system in case of an emergency, and shall hand over to the user 

the warnings handbook supplied with the product.

 21)  Do  not  allow  children  or  adults  to  stay  near  the  product  while  it  is 

operating.

 22)  Keep remote controls or other pulse generators away from children, to 

prevent the automated system from being activated involuntarily.

 23)  Transit under the door must occur only when the automated system 

has stopped.

 24)  The user must not attempt any kind of repair or direct action whatever 

and contact qualified personnel only.

 25)  Maintenance:  check  at  least  every  6  months  the  efficiency  of  the 

system, particularly the efficiency of the safety devices (including, where 

foreseen, the operator thrust force) and of the release devices.

 26)  Anything not expressly specified in these instructions is not permitted.

WARNINGS FOR THE INSTALLER

GENERAL SAFETY OBLIGATIONS

CE DECLARATION OF CONFORMITY FOR MACHINES

(DIRECTIVE 

00/

/EC)

Manufacturer: 

FAAC S.p.A.

Address:

 

Via Benini, 1  - 40069  Zola Predosa BOLOGNA - ITALY

Declares that: 

Operator model   D064 with E064

is built to be integrated into a machine or to be assembled with other machinery to create a machine under the provisions of Directive
2006/42/EC

conforms to the essential safety requirements of the following EEC directives

   

2006/95/EC    Low Voltage directive 

2004/108/EC  Electromagnetic Compatibility directive 

and also declares that it is prohibited to put into service the machinery until the machine in which it will be integrated or of which

it will become a component has been identified and declared as conforming to the conditions of Directive 2006/42/EC

Bologna, 01 April 2008

 

   

 

 

 

 

The Managing Director

 

A. Bassi

FAAC S.p.A.

Via Benini, 1

40069 Zola Predosa (BO) - ITALIA

Tel.  0039.051.61724 - Fax.  0039.051.758518

www.faac.it

www.faacgroup.com

732559 - Rev. A 

Содержание D064

Страница 1: ...D064...

Страница 2: ...ust not encroach public areas dedicated to pedestrian or vehicular transport Check the efficiency of the door bearings and joints Make sure that the door is friction free If necessary clean and lubric...

Страница 3: ...contact with moving parts Install the fixed control points at a minimum height of 150 cm clear of the door movement area but in a position enabling visual control of that area Cable 2 x 0 5 mm2 TX ph...

Страница 4: ...ONLY FOR EXTERNAL MECHANICAL RELEASE 4 5 1 3 2...

Страница 5: ...max 20 cm max 40 cm 15 20 OPTIONAL ONLY FOR EXTERNAL MECHANICAL RELEASE 6 7 7 8 9 J K L...

Страница 6: ...top Fsw CLOSED Opens No effect 2 No effect OPENING Locks Locks 2 No effect 1 OPEN Closes No effect 2 No effect 1 CLOSING Reverses motion Locks 2 Reverses motion LOCKED Closes No effect 2 No effect 1 S...

Страница 7: ...input is not used jumper connect the input to the terminal If the photocells are not used connect the FSW input to terminal TX FSW Input status LEDS The automated system stopped and at rest is indica...

Страница 8: ...unit independently determines the movement parameters If the procedure is not correctly concluded e g due to excessive friction during door movement the unit signals a fault status the SET UP LED flas...

Страница 9: ...y During these 5 seconds in order to lighten the load on the release system you can send OPEN pulses within a time interval of 2 seconds from each other in order to reverse the carriage One pulse corr...

Страница 10: ...within which time the code of another radio control must be transmitted 6 The LED lights up on steady beam for 2 seconds indicating memory storage executed and then resumes flashing for 5 sec during...

Страница 11: ...perform any movement STOP command enabled The automated system opens the door but does not close it FSW safety devices engaged The Fail Safe function is enabled but the NC contact of the devices conne...

Страница 12: ...gging and shearing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequately secured to the frame structure in addition to the devices m...

Отзывы: