manualshive.com logo in svg
background image

10

OPEN B

OPEN A

RADIO SET UP

8.3 Memory storage of radio controls  RC / LC 

 

A Maximum of 250 codes can be memory stored, split 

between OPEN A and OPEN B.

1)  Use  LC/RC  remote  controls  only  with  receiver  module  at 

433 MHz. 

2) To respectively memory store total or partial opening, press 

the OPEN A or OPEN B push-button for one second (Fig. 7 

  ref. 

).

3) The relevant LED starts to flash slowly for 5 sec.

4) Within these 5 secs., press the appropriate push-button on 

the LC/RC remote control.

5) The LED lights up on steady beam for 1 second, indicating 

memory storage executed, and then resumes flashing for 

another 5 sec., during which another radio control (point 4) 

can be memory stored.

6) When the 5 secs. have elapsed, the LED goes OFF indicating 

the end of the procedure.

7) To add other radio controls, repeat the operation from point 

1

Fig.6

8.3.1 Remote memory storage of RC/LC radio  

controls

Other  radio  controls  can  be  remotely  stored  only  with  the 

RC/LC

radio controls, i.e. without using the RADIO SETUP 

push-buttons, but using a previously stored radio control.

Fig. 7

1)  Obtain  a  radio  control  already  stored  on  one  of  the  2  

channels (OPEN A or OPEN B).

2) Press and simultaneously hold down push-buttons P1 and P2 

until the lights of both the LEDs on the board light up.

3) Both LEDs flash slowly for 5 sec.

4) Within 5 sec. press the push-button of the radio control that   

had been memory stored to enable learning on the selected 

channel (OPEN A or OPEN B).

5) The LED on the board relating to the channel being learned 

flashes for 5 sec., within which time the code of another radio 

control must be transmitted.

6) The LED lights up on steady beam for 2 seconds, indicating 

memory storage executed, and then resumes flashing for 5 

sec., during which other radio controls can be memory stored, 

as in point 5, and then goes OFF.  

8.4 Radio controls deletion procedure

1) To delete 

ALL

 the radio control codes, hold down push-button 

OPEN A or OPEN B for 10 sec.

2) The LED relating to the pressed push-button flashes for the first 

5 sec, and then flashes more quickly for the next 5 sec.

3) Both LEDs light up on steady beam for 2 sec and then go 

OFF.

4) Release the pressed push-button when both LEDs light up on 

a steady beam.

 

This operation is NOT reversible.

 All codes of radio controls stored as OPEN A and OPEN 

B will be deleted.

 9 START-UP

 

 After installation, make sure that no part of the door 

interferes  with  public  spaces  such  as  pavements  and/or 

roads.

Check the status of the unit’s inputs and make sure that all the 

safety devices are correctly connected (the relevant LEDs must 

be lighted).

Run a few complete cycles to check if the automated system  

and the accessories connected to it are operating correctly,  

addressing  special  care  to  the  safety  devices  and  the  

anti-crushing device of the operator. Check if the automated 

system is able to detect an obstacle with a height of 50mm 

laid on the ground.

Apply the stickers indicating the release manoeuvre near the 

automated system. Apply the danger signal sticker (Fig. 8), so 

that it is clearly visible, near to the door or near to the control 

device.

Hand  the  customer  the  page  entitled  “User’s  guide”,  and 

describe how the system works, and the operator release and 

locking operations indicated in the guide.

Fig. 8

Содержание D064

Страница 1: ...D064...

Страница 2: ...ust not encroach public areas dedicated to pedestrian or vehicular transport Check the efficiency of the door bearings and joints Make sure that the door is friction free If necessary clean and lubric...

Страница 3: ...contact with moving parts Install the fixed control points at a minimum height of 150 cm clear of the door movement area but in a position enabling visual control of that area Cable 2 x 0 5 mm2 TX ph...

Страница 4: ...ONLY FOR EXTERNAL MECHANICAL RELEASE 4 5 1 3 2...

Страница 5: ...max 20 cm max 40 cm 15 20 OPTIONAL ONLY FOR EXTERNAL MECHANICAL RELEASE 6 7 7 8 9 J K L...

Страница 6: ...top Fsw CLOSED Opens No effect 2 No effect OPENING Locks Locks 2 No effect 1 OPEN Closes No effect 2 No effect 1 CLOSING Reverses motion Locks 2 Reverses motion LOCKED Closes No effect 2 No effect 1 S...

Страница 7: ...input is not used jumper connect the input to the terminal If the photocells are not used connect the FSW input to terminal TX FSW Input status LEDS The automated system stopped and at rest is indica...

Страница 8: ...unit independently determines the movement parameters If the procedure is not correctly concluded e g due to excessive friction during door movement the unit signals a fault status the SET UP LED flas...

Страница 9: ...y During these 5 seconds in order to lighten the load on the release system you can send OPEN pulses within a time interval of 2 seconds from each other in order to reverse the carriage One pulse corr...

Страница 10: ...within which time the code of another radio control must be transmitted 6 The LED lights up on steady beam for 2 seconds indicating memory storage executed and then resumes flashing for 5 sec during...

Страница 11: ...perform any movement STOP command enabled The automated system opens the door but does not close it FSW safety devices engaged The Fail Safe function is enabled but the NC contact of the devices conne...

Страница 12: ...gging and shearing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequately secured to the frame structure in addition to the devices m...

Отзывы: