These instructions apply to model 

FAAC D064

.

The  D064  automated  systems  make  it  possible  to  automate  

balanced  sectional  doors  of  single  garages  for  residential 

use.

They  consist  of  an  electro-mechanical  operator,  electronic  

control unit and courtesy light built into a single unit. This unit is  

fitted to the ceiling and opens the door by means of a transmission  

chain or belt.

The  system  is  non-reversing  and,  therefore,  the  door  locks  

mechanically when the motor is not operating and, consequently,  

no lock is necessary; two manual releases, one on the inside 

and one on the outside (optional) make it possible to move the 

door in case of a power cut or fault.

The operator is supplied with an electronic device that detects 

the presence of an obstacle that would hinder door movement 

-  the device prevents crushing or lifting. 

This instruction refers to the operator with chain drive, but the 

same procedures, regulations and application limits apply also 

to the belt driven operator.

The D064 automated systems were designed and built for 

indoor use and to control vehicle access. Do not use them for 

any other purpose.

AUTOMATED SYSTEM D064

 1 PRELIMINARY CHECKS

- The structure of the door must be suitable for fitting automation.  

In  particular,  check  that  the  door  dimensions  conform  to 

those indicated in the technical specifications, and that it is 

sufficiently sturdy.

-  Check  if  the  door  conforms  to  standards  EN12604  and 

EN12605.

-  As  it  moves,  the  door  must  not  encroach  public  areas  

dedicated to pedestrian or vehicular transport.

- Check the efficiency of the door bearings and joints.

-  Make  sure  that  the  door  is  friction-free.  If  necessary  clean 

and lubricate the guides with silicone based products, but do 

not use grease, and, in any event, follow the manufacturer’s 

instructions.

- Check correct balance and if the opening mechanical stops 

have been installed.

- Remove the door’s existing closing mechanism to ensure the 

door is closed by the automated system.

- Make sure there is a clearance of at least 35 mm between the 

ceiling and the highest sliding point of the door .

- Check if the upper guide roller of the sectional door is in the 

horizontal part of the guide while the door is closed.

 2 TECHNICAL SPECIFICATIONS

Model

D064

Power supply (V ~ / 50 Hz.)

230

Electric motor (Vdc)

24

Maximum absorbed power (W)

220

Thrust force (N)

550

Type of use

Residential

Maximum dimensions from ceiling (mm)

35 

Courtesy light (V ~/W)

230 / 40 max.

Courtesy light timer (sec)

120

Standard speed with no-load carriage (m/min)

6,6

Slow speed with no-load carriage (m/min)

3,8

Carriage deceleration speed (m/min)

1,3

Travel length at deceleration

varies according to set-up

Intrinsic safety device 

Category 2

Maximum sectional door width (mm)

5000

Maximum sectional door  height (mm)

2600

Sliding guide useful travel (mm)

2600

Protection class

for indoor use only (IP20)

Operating ambient temperature (°C)

-20 / +55

  Ceiling lamp

  Rear door

  Courtesy light

  Plastic housing for D064 operator 

  Rear fitting

  Sliding guide

  Drive carriage

 

Release knob

  Door fitting bracket

  Transmission unit

  Front fitting and chain tensioner

  Front fitting bracket

Содержание D064

Страница 1: ...D064...

Страница 2: ...ust not encroach public areas dedicated to pedestrian or vehicular transport Check the efficiency of the door bearings and joints Make sure that the door is friction free If necessary clean and lubric...

Страница 3: ...contact with moving parts Install the fixed control points at a minimum height of 150 cm clear of the door movement area but in a position enabling visual control of that area Cable 2 x 0 5 mm2 TX ph...

Страница 4: ...ONLY FOR EXTERNAL MECHANICAL RELEASE 4 5 1 3 2...

Страница 5: ...max 20 cm max 40 cm 15 20 OPTIONAL ONLY FOR EXTERNAL MECHANICAL RELEASE 6 7 7 8 9 J K L...

Страница 6: ...top Fsw CLOSED Opens No effect 2 No effect OPENING Locks Locks 2 No effect 1 OPEN Closes No effect 2 No effect 1 CLOSING Reverses motion Locks 2 Reverses motion LOCKED Closes No effect 2 No effect 1 S...

Страница 7: ...input is not used jumper connect the input to the terminal If the photocells are not used connect the FSW input to terminal TX FSW Input status LEDS The automated system stopped and at rest is indica...

Страница 8: ...unit independently determines the movement parameters If the procedure is not correctly concluded e g due to excessive friction during door movement the unit signals a fault status the SET UP LED flas...

Страница 9: ...y During these 5 seconds in order to lighten the load on the release system you can send OPEN pulses within a time interval of 2 seconds from each other in order to reverse the carriage One pulse corr...

Страница 10: ...within which time the code of another radio control must be transmitted 6 The LED lights up on steady beam for 2 seconds indicating memory storage executed and then resumes flashing for 5 sec during...

Страница 11: ...perform any movement STOP command enabled The automated system opens the door but does not close it FSW safety devices engaged The Fail Safe function is enabled but the NC contact of the devices conne...

Страница 12: ...gging and shearing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequately secured to the frame structure in addition to the devices m...

Отзывы: