1) CAUTION! It is important  for personal safety to follow all the instructions

carefully. Incorrect installation or misuse of the product  may cause
people serious harm.

2) Read the instructions carefully before starting to install the product.

3) Packaging material (plastic, polystyrene, etc.) must not be left within reach

of children as it is a potential source of danger.

4) Keep the instructions  for future reference.

5) This product was designed and manufactured strictly for the use indicated

in this documentation. Any other not expressly indicated use may damage
the product and/or be a source of danger.

6) FAAC accepts no responsibility due to improper use of the automated

system or use other than that intended.

7) Do not install the equipment in an area subject to explosion hazard:

inflammable gases or fumes are a serious safety hazard.

8) The system must be carried out in compliance with the following Standards:

EN 12604, EN 12605, EN 12453, EN 12445. To obtain an adequate level of
safety in non EU countries, the above mentioned  Standards must be
observed in addition to national Standards.

9) FAAC will not accept responsibility if the principles of Good Workmanship

are disregarded in constructing the closing elements to be motorised, and
if any deformation occurs during use of the said elements.

10) Before carrying out any work on the system, switch off the power supply.

11) The mains power  supply of the automated system must be fitted with a all-

pole  switch with contact opening distance of 3mm or greater. Use of a 6A
thermal breaker with all-pole circuit break is recommended.

12) Make sure there is a differential switch with 0.03A threshold upstream of the

system.

13) Check that the earthing system is correctly made and connect the closure

metal parts to it.

14) The automated system includes an intrinsic anti-crushing device consisting

of a torque control which, however, must be installed together with other
safety devices.

15) The safety devices (EN 12978 Standard) protect any dangerous areas

against 

Mechanical movement risks

, such as crushing, dragging, and

shearing.

CE DECLARATION OF CONFORMITY FOR MACHINES

(DIRECTIVE 98/37/EC)

Manufacturer:

FAAC S.p.A.

Address:

Via Benini, 1  - 40069  Zola Predosa BOLOGNA - ITALY

Declares that:

940 SM - SMD mod. operator

• is built to be integrated into a machine or to be assembled with other machinery to create a machine under

the provisions of Directive 98/37/EC;

• conforms to the essential safety requirements of the following EEC directives:

73/23/EEC and subsequent amendment  93/68/EEC.
89/336/EEC and subsequent amendment  92/31/EEC and 93/68/EEC

and also declares that it is prohibited to put into service the machinery until the machine in which it will be
integrated or of which it will become a component has been identified and declared as conforming to the
conditions of Directive 98/37/EC.

Bologna, 01 January 2003

The Managing Director

A. Bassi

16) A warning sign adequately fitted on the leaves, in addition to the devices

mentioned under point "15", must be used for each system.

17) FAAC accepts no responsibility regarding safety and correct operation

of the automated system,  should components made by manufacturers
other than FAAC be  used in the system.

18) Use only FAAC original spare parts for  maintenance.

19) Do not make any alterations to the components of the automated system.

20) The installer shall supply full information regarding manual operation of

the system in case of an emergency.

21) Do not allow children or other persons to stand near the product while in

operation.

22) Keep remote controls or any other pulse generator well away from

children, to prevent the automated system from being activated
accidentally.

23) The user must refrain from attempting to repair or adjust the system

personally and should contact qualified personnel only.

24) Anything not expressly provided for in these instructions is not permitted.

WARNINGS FOR THE INSTALLER

GENERAL SAFETY OBLIGATIONS

Содержание 940SM Series

Страница 1: ...940SM SMD 940SM SMD para la naturaleza 100 papel reciclado ist umweltfreundlich 100 Altpapier pour la nature papier recycl 100 for nature recycled paper 100 carta riciclata 100 per la natura...

Страница 2: ...withother safetydevices 15 The safety devices EN 12978 Standard protect any dangerous areas against Mechanical movement risks such as crushing dragging and shearing CE DECLARATION OF CONFORMITY FOR MA...

Страница 3: ...H KEY TO PROFILES SUPPORT PROFILE HOUSING PROFILE SLIDING PROFILE CLOSING PROFILE FOR STANDARD AUTOMATED SYSTEM LEAF ATTACHMENT PROFILE LEAF BOTTOM PROFILE GRIPPER FOR GLASS LEAVES BOTTOM SLIDING BLOC...

Страница 4: ...d power Power supply Protection class Anti crushing activation Operating ambient temperature Use frequency Motor power supply Head profile length Opening speed adjustment load free Closing speed adjus...

Страница 5: ...4 ENGLISH ENGLISH 15 15 9 5 179 5 34 5 10 25 50 130 5 40 100 180 173 Fig 2...

Страница 6: ...red and tested in the configuration requested by the customer on the order form or supplied as a kit An automation head profile fig 1 consists of the following parts Profile SM fig 2 ref This is the s...

Страница 7: ...790 1735 4470 2165 2100 4300 1890 1835 4670 2265 2200 4500 1990 1935 4870 2365 2300 4700 2090 2035 5070 2465 2400 4900 2190 2135 5270 2565 2500 5100 2290 2235 5470 2665 2600 5300 2390 2335 5670 2765 2...

Страница 8: ...790 1785 4470 2165 2100 4300 1890 1885 4670 2265 2200 4500 1990 1985 4870 2365 2300 4700 2090 2085 5070 2465 2400 4900 2190 2185 5270 2565 2500 5100 2290 2285 5470 2665 2600 5300 2390 2385 5670 2765 2...

Страница 9: ...5110 2485 2100 4300 875 857 5 5310 2585 2200 4500 925 907 5 5510 2685 2300 4700 975 957 5 5710 2785 2400 4900 1025 1007 5 5910 2885 2500 5100 1075 1057 5 6110 2985 2600 5300 1125 1107 5 6310 3085 2700...

Страница 10: ...2165 2100 4300 1890 1735 4670 2265 2200 4500 1990 1835 4870 2365 2300 4700 2090 1935 5070 2465 2400 4900 2190 2035 5270 2565 2500 5100 2290 2135 5470 2665 2600 5300 2390 2235 5670 2765 2700 5500 2490...

Страница 11: ...00 4100 1790 1685 4470 2165 2100 4300 1890 1785 4670 2265 2200 4500 1990 1885 4870 2365 2300 4700 2090 1985 5070 2465 2400 4900 2190 2085 5270 2565 2500 5100 2290 2185 5470 2665 2600 5300 2390 2285 56...

Страница 12: ...4910 2385 2000 4100 825 807 5 5110 2485 2100 4300 875 857 5 5310 2585 2200 4500 925 907 5 5510 2685 2300 4700 975 957 5 5710 2785 2400 4900 1025 1007 5 5910 2885 2500 5100 1075 1057 5 6110 2985 2600 5...

Страница 13: ...12 ENGLISH ENGLISH 5 INSTALLATION Fig 9 140 9 5 10 HA LH 20 5 mm 10 LH max 2500 HA...

Страница 14: ...0 6 1 Installation of side panels Fit the side panels as shown in figures 12 The side panels are engraved so that they can adapt to head profiles with or without a free standing profile Fig 12 7 INSTA...

Страница 15: ...as follows Take the leave into opening position Loosen the two hexagon head screws as shown in figures 18 and 19 ref Take the mechanical stop toward the carriage until the two parts come into contact...

Страница 16: ...t always be installed even if the motor lock is not used Fig 23 Fig 24 12 MOTOR LOCK The motor lock is a device guaranteeing the leaves are lockedwhenclosed Installationprocedure Secure the motor lock...

Страница 17: ...s limit stop compressing the springs and tighten the screw of the terminal thus securing the steel cable Make sure that the motor lock coupling is clear of the motor shaft coupling fig 26 ref B If adj...

Страница 18: ...S Fit the buffer batteries inside the transformer unit fig 35 Fig 35 Fig 32 R 20 40 40 50 Fig 33 14 INSTALLATION OF CABLE SLEEVES Fit the supplied cable sleeves parallel to the profile fig 34 ref and...

Страница 19: ...18 ENGLISH ENGLISH Fig 36 16 INSTALLATION WITH GRIPPERS FOR GLASS LEAVES HA LH 4 5 23 5 21 10mm To install with the glass leaves grippers refer to the dimensions infigure 36 LH max 2500 HA...

Страница 20: ...m the toroidal transformer from the motor and from all accessories routing the cables inside the pre fittedcablesleeves Set motor direction of rotation according to type of door refer to the instructi...

Страница 21: ...S MEANING OFF normal operating status ON Alarms n 18 20 22 24 execute SETUP SLOW FLASHING current alarm signalling FAST FLASHING setup reset in progress or during setup with the kit elastic activated...

Страница 22: ...g J2 connector to J1 of 940SDM J3 connector to J2 of 940SDM J4 transformer 24V secondary winding J5 connector to J9 of 940SDM J6 second motor quick fit connector J7 not used J8 RS232 serial port for P...

Страница 23: ...J7 J10 J5 J9 J8 J8 J1 J3 J7 J2 J4 fig 1 fig 2 J10 J1 J2 J6 J9 J3 J4 J7 J5 J1 J3 J7 J2 J4 J9 J1 J2 J3 second motor motor Second motor board 940SDM board Batteries board transformer 40V secondary windi...

Страница 24: ...ISABLED DEFAULT no photocell 1 pair of photocells 2 pairs of photocells PSW 2 PSW 1 FAILSAFE VACC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RX1 TX1 C J5 PSW 2 PSW 1 FAILSAFE VACC 1 2 3 4 5 6 7 8 9 10 11 12 13...

Страница 25: ...tact J6 TERMINAL BOARD J6 TERMINAL BOARD J6 TERMINAL BOARD J6 TERMINAL BOARD J6 TERMINAL BOARD 1 24V 24V power supply for accessories The total maximum load of the accessories connected to the VACC an...

Страница 26: ...Keeper Display as an alternative one photocell only can be set connecting it to the PSW1 input as usual thus disabling the PSW2 input and avoiding the jumper see the SD Keeper programming instruction...

Страница 27: ...nt partial opening and re closing after pause time no effect no effect no effect no effect restarts pause time count total opening and re closing after pause time restarts pause time count partial ope...

Страница 28: ...IAGNOSTICS DIAGNOSTICS DIAGNOSTICS DIAGNOSTICS DIAGNOSTICS SD Keeper also without display has a diagnostic function which in case of an alarm interrupts normal display of the function every 2 seconds...

Страница 29: ...range of pause time 0 to 90 sec DOOR OPEN DOOR OPEN DOOR OPEN DOOR OPEN DOOR OPEN The door opens and stays open NIGHT NIGHT NIGHT NIGHT NIGHT The door closes and the lock if present is activated The i...

Страница 30: ...OK key An asterisk on the display indicates the currently active setting To exit programming select the exit function at each level Otherwise after about 2 minutes the display automatically returns to...

Страница 31: ...OK OK OK 4 1 OK OK OK 4 2 OK OK 4 3 4 OK OK OK OK OK OK 5 OK OK 5 1 5 2 OK OK OK BATTERY BATTERY KIT ON OFF NO STANDARD STANDARD BAT OPERATION OPENING NO STANDARD STANDARD CLOSING NIGHT BATT LAST OPER...

Страница 32: ...1 OK OK OK OK OK OK OK 1 1 1 2 1 3 1 4 2 3 4 OK OK OK OK OK OK PASSWORD 0000 ADVANCED MENU PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 OPERATION PARAMETERS CLOSING SPEED OPENING SPEED DECEL WIDTH DECEL...

Страница 33: ...OK OK PASSWORD 0000 ADVANCED MENU PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 incorrect code correct code OPERATION PARAMETERS IN OUT SETUP VARIOUS EXIT CHANGE PASSWORD EMERG 1 OPEN STOP CLOSE SPEED NO...

Страница 34: ...K OK OK OK OK OK OK 3 3 PASSWORD 0000 ADVANCED MENU PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 incorrect code correct code OPERATION PARAMETERS IN OUT SETUP VARIOUS EXIT CHANGE PASSWORD STAND SETUP STA...

Страница 35: ...AND 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 TIME BAND 4 FUN 0 00 00 TIME BAND 3 FUN 0 00 00 TIME BAND 1 FUN 0 00 00 TIME BAND 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 TIME BAND 4 FUN 0 00 00 TIME BAND 3 FU...

Страница 36: ...at the point where the obstacle had been detected and continues at the slower speed until completed Opening No Standard Opening No Standard Opening No Standard Opening No Standard Opening No Standard...

Страница 37: ...value 0 cm Adjusting range from 0 to 120 cm Closing Closing Closing Closing Closing Sets anticipated time value on the standard deceleration point at the closing stop position Standard value 0 cm Adju...

Страница 38: ...a black out Off Off Off Off Off Elastic kit not installed On On On On On Elastic kit installed Standard Standard Standard Standard Standard When power is restored after a blackout the door remains set...

Страница 39: ...execute the Setup activate the elastic kit with SD Keeper Display install the accessory mechanically After installation the leaves will open when mains power fails when mains power is restored the ela...

Страница 40: ...ient reserve charge to perform at least one emergency movement after which the 940SDM control board goes into NIGHT ENERGY SAVING status ENERGY SAVING other than Night operating function VAC is switch...

Страница 41: ...the sensor of the second door 6 Door B opens 7 The person exits 8 Door B closes after the night pause time elapses The operation is identical if the person comes from the opposite direction INTERLOCK...

Страница 42: ...RY function was selected for theEMERG2input whenthecontactisrestored RESET is necessary to cancel the signal 3 4 7 EMERG 1 ON Emergency input 1 active This signal is shown whenever the EMERG1 emergenc...

Страница 43: ...execute a new SETUP 2 4 22 The SETUP procedure cannot be completed because excessive friction or excessive leaf weight was detected When this signal is generated the ERROR LED on the 940SDM control bo...

Страница 44: ...alarm in progress connect the SD Keeper to find the alarm and take the appropriate action see the diagnosticsguide G door locked and ERROR LED ON SETUPmustbeexecuted alarm in progress connect the SD K...

Страница 45: ...ra cualquier otro tipo de exigencia de car cter constructivo o comercial Timbro del Rivenditore Distributor s Stamp Timbre de l Agent Fachh ndlerstempel Sello del Revendedor FAAC S p A Via Benini 1 40...

Отзывы: