XTP T HWP 101 4K Wallplate Transmitter • SIS Configuration and Control
18
SIS Configuration
and Control
This section contains SIS communication details and SIS commands and responses when
the host device is connected directly to an XTP T HWP 101 4K. Topics in this section
include the following:
•
•
•
Command and Response Table for SIS Commands
Host Device Connection
Use a connected computer running the Extron DataViewer utility to send and receive SIS
commands and responses. To connect directly to an XTP T HWP 101 4K, connect the
computer to the rear panel USB configuration connector (see
figure 5
,
C
on page 8).
SIS Overview
Host and Device Communication
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the XTP T HWP 101 4K determines
that a command is valid, it executes the command and sends a response to the host
device. All responses from the transmitter to the host device end with a carriage return and
a line feed (CR/LF =
]
), which signals the end of the response character string. A string is
one or more characters.
Error Responses
If the transmitter determines a command is invalid or contains invalid parameters, it returns
an error response to the host. The following error codes may apply to the device:
E10
= Invalid command
E13
= Invalid parameter
E14
= Not valid for this configuration
E17
= Invalid command for signal type
E22
= Busy
Содержание XTP T HWP 101 4K
Страница 6: ......
Страница 8: ...XTP T HWP 101 4K Wallplate Transmitter Contents viii ...