Room Scheduling System • Reference Information
88
Occupancy Sensor Configuration
TLS 520M, TLS 525M, TLP Pro 520M, TLS 725M, and TLS 1025M panels have digital I/O
connectors necessary to connect room occupancy sensors. Figure 91 shows how to wire
the sensors to the panels and configure the panels.
NOTES:
•
Figure 104 shows the Extron OCS 100C (ceiling) Occupancy Sensors. OCS 100W
(wall) sensors are wired identically. If you use other sensors, check the connections
and wiring in the documentation for your sensors.
•
Figure 104 is a configuration drawing only and does not show power to the
sensors.
Ground (Black)
Control Connections
Relay Connections
(normally closed)
Control (Blue)
Common (Blue/White)
Normally Closed
(Black/White)
Relay Connections
(normally open)
Common (Blue/White)
Normally Open
(Yellow/White)
Extron
TLS 520M
Touchpanel
OCS 100C
Occupancy Sensor
OCS 100C
Occupancy Sensor
OCS 100C
Occupancy Sensor
Extron
TLS 520M
Touchpanel
Extron
TLS 520M
Touchpanel
Extron
Extron
Extron
Extron
Extron
Extron
Figure 104.
Occupancy Sensor Connection and Panel Configuration