Quantum Ultra Series Videowall Processing Systems • Remote Configuration and Control
76
Command
ASCII Command
(Host to Processor)
Response
(Processor to Host)
Additional Description
Information Requests
General information
X#
*
X%
*
I
Grp
X#
•
Win
X%
•
In
X!
•
Typ
X$
•
Blk
X4@
•
Res
X8)
•
Vrt
X1#]
(Responses are the same in verbose modes 2 and 3.)
View canvas (output group),
window, input selection,
source type, mute status,
input resolution, and vertical
frequency.
Query model name
1I
X^
]
In verbose modes 2 and 3:
Inf01
*
X^
]
View Quantum Ultra model
name
X^
.
Query firmware version
Q
n.nn
]
In verbose modes 2 and 3:
Ver01
*
n.nn
]
View firmware version to the
second decimal place.
Query firmware build
version
*Q
n.nn.nnnn-bnnn
]
In verbose modes 2 and 3:
Bld
n
.nn.
nnnn
-
bnnn
]
View the full firmware version.
Query part number
N
X&
]
In verbose modes 2 and 3:
Pno
X&
]
View the Quantum Ultra part
number.
View internal temperature
E
20STAT
}
X1@
]
In verbose modes 2 and 3:
20Stat
•
X1@
]
View unit internal temperature
X1@
in degrees Celsius.
View SBC temperature
E
21STAT
}
X1@
]
In verbose modes 2 and 3:
21Stat
•
X1@
]
View temperature
X1@
of the
internal controller (SBC) in
degrees Celsius.
View I/O card
temperature
E
22STAT
}
X1@
]
In verbose modes 2 and 3:
22Stat
•
X1@
]
View temperature
X1@
of the
hottest input or output card.
KEY:
X!
= Input number:
0
through
9999
(assigned by the VCS program). Response is four digits with leading zeros.
0
= Window without source.
1-999
= Physical video connections on all chassis in the system.
1000-9999
= VNC, image, text, and clock sources defined in the system
X#
= Canvas number:
1
through
10
. Response is two digits with leading zero.
0
= All canvases (for window mute and preset recall only)
X$
= Source format:
0
= No signal present,
1
= HDMI,
4
= H.264/MJPEG,
5
= VNC,
6
= Clock,
7
= Image file (.bmp,
.jpg, .tif, or .png)
X%
= Window number:
1
through
999
. Response is three digits with leading zeros.
0
= All windows (for window mute only)
X^
=
Quantum
Ultra
610
,
Quantum
Ultra
305
,
Quantum
Ultra
II
610
,
Quantum
Ultra
II
305
,
Quantum
Ultra
Connect
128
, or
Quantum
Ultra
Connect
84
X&
=
Quantum Ultra 610
=
60-1571-01
or
60-1990-01
Quantum Ultra 305
=
60-1734-01
or
60-1989-01
Quantum Ultra II
610
=
60-1900-01
Quantum Ultra II 305
=
60-1899-01
Quantum Ultra Connect 84
=
60-1898-01
or
60-1898-11
Quantum Ultra Connect 128
=
60-1898-02
or
60-1898-12
X1@
= Internal temperature in degrees Celsius.
X1#
= Vertical frequency: Response format is three digits with leading zeros and one decimal place.
X4@
= Window mute:
0
= Off (unmute) (default),
1
= On (mute window)
X8)
=
Input resolution: Horizontal and vertical dimensions.