Quantum Ultra Series Videowall Processing Systems • Installation and Configuration
14
6.
Connect AC power to the IEC connectors of the Quantum Ultra Series primary and
redundant (optional, 610 models only) power supplies.
NOTE:
Temperature controlled fans run at 100% as a failsafe if only one power
supply is operational.
7.
Power on the processor and all connected devices.
8.
Download and install VCS on your computer (see
9.
The default IP addresses of the Quantum Ultra Series chassis are:
•
LAN A:
192.168.254.254
•
LAN B:
192.168.1.254
Set a new IP address for the processor using any of the following:
•
VCS program
— The Videowall Configuration Software for the Quantum Ultra
Series can be downloaded from the Extron website (see
on page 81). Run this program on a computer that is
connected to the same network as the Quantum Ultra Series device to assign an
IP address to the processor (see the
VCS Help File
for instructions).
NOTE:
A gateway IP address is required on the PC running VCS for the
Quantum Ultra Series to be detected. The gateway IP address does not
need to be valid or in the same subnet for the detection to work.
•
Internal operating system
— The Quantum Ultra Series processor is a host
device with an embedded Windows operating system. To interact with the
operating system to change settings, attach peripheral USB devices, such as a
keyboard, mouse, and flash drive, to System USB ports 1, 2, and 3 on the rear
panel. Attach an HDMI monitor to the HDMI Out port beside the System ports to
view the settings.
•
SIS commands
— Using a host communication software program such as the
Extron DataViewer on your computer, enter the appropriate SIS command to set
an IP address or enable DHCP (see
10.
Configure sources, displays, and presets for your videowall system using VCS (see
the
VCS Help File
).