NAV E 401 D and NAV E 201 D Encoders • Troubleshooting
70
Alarm
Cause
Remedy
Stream
Conflict
Multiple NAV endpoints are configured
to use the same video, audio, AES67, or
USB multicast IP address.
Reconfigure endpoint stream settings for
a unique stream address.
Temperature
Interna
l
The NAV device is overheating.
Check the ambient temperature of the
NAV device installation location.
•
If greater than 104 °F, (60 ºC) use
HVAC system to lower ambient
temperature.
•
If ambient temperature is
104 °F, (60 °C) or less, check
the mounting location for nearby
equipment emitting excessive heat.
Tie
Failure
The encoder failed to establish a tie with
the specified endpoint.
Debug the network connectivity between
the encoder and decoder.
Video
loss
The input is changed and video sync
cannot be established for within a two-
second window.
Debug the connectivity of the AV source
device to the NAV encoder.