background image

32

ENGLISH

1.

 Extraflame S.p.A. products are guaranteed, within the European community, for 24 months from the date of purchase. 

Purchase has to be proved by means of a valid fiscal document issued by the seller (receipt, invoice or shipment document) identifying the 

purchased product and its purchase and/or delivery date. 

Warning: This conventional guarantee does not replace the guarantee regulated by the European legislation on consumer rights.

The conventional guarantee is only applicable to the Italian region and to those areas, within the European Community, where the Authorised 

Technical Assistance Centres are active (see the www.lanordica-extraflame.com website)

It is also limited to the state of residence of the consumer, which must coincide with the premises and/or registered office of the seller of the 

Extraflame S.p.A. product 

These regulations do not apply if the product is purchased within commercial, entrepreneurial, or professional circumstances. In these cases 

the product guarantee will be limited to a period of 12 months from the date of purchase. 

ITALIAN GUARANTEE

What must be done if there is a product malfunction: 

Consult the instructions manual to make sure the malfunction cannot be solved by using the product correctly.  Make sure the malfunction is 

included in those covered by the guarantee; otherwise the cost of the intervention will be borne entirely by the consumer. When requesting 

the intervention of the Assistance service at the Authorised Assistance Centre, always specify: - type of malfunction - model of the appliance 

- complete address - phone number

EUROPEAN GUARANTEE

What must be done if there is a product malfunction: 

Consult the instructions manual to make sure the malfunction cannot be solved by using the product correctly. Make sure the malfunction 

is included in those covered by the guarantee; otherwise the cost of the intervention will be borne entirely by the consumer. Request the 

intervention of the Assistance service or the address of the Authorised Technical Assistance Centre to the seller; always specify: type of 

malfunction, model of the appliance, complete address and phone number

if the malfunction arises in the first 6 months of the product's life, the consumer has the right to have the product repaired with no expense. 

From the seventh to the twenty-fourth month, if a malfunction arises, the consumer will bear the cost of the call, while the seller will pay for the 

manpower and for any spare parts used.

2.

 If the malfunction is linked to external events and/or conditions such as, including but not limited to, insufficient capacity of the systems; 

wrong installation and/or maintenance by the personnel which hasn't got the skills prescribed by the laws of the country of residence of 

the consumer; negligence; inability to use the product and wrong maintenance by the consumer, with respect to what is reported and 

recommended by the instructions manual of the product, which is part of the sales contract, this guarantee will be void. 

Damage to the product that cannot be related to manufacturing defects are also not included in this guarantee. Similarly are excluded defects 

related to incorrect operation of the flue, according to the legislation in force in the country at the moment of purchase. Other exclusions 

include all product defects due to carelessness, accidental breakdown, tampering and/or damage during transport (scratches, dents, etc.), 

interventions carried out by unauthorised personnel and further damage caused by incorrect interventions by the consumer trying to arrange 

the initial malfunction. 

The following consumables are excluded by the guarantee: gaskets, ceramic or tempered glasses, cast iron grilles or coatings, refractory 

materials (e.g. Nordiker or others), painted, chrome-plated or golden parts, majolica ware, handles, the brazier and its related components. 

For Idro products the heat exchanger is not covered by the guarantee if a suitable condensation-proof circuit is not set up to ensure a return 

temperature of the device of at least 55°C. The guarantee excludes all the external components on which the consumer can directly operate 

during use and/or maintenance or that can be subject to wear and/or rust and stains on steel due to aggressive detergents. 

If malfunctions are signalled which are not later confirmed during check by an authorised technician, the cost of the intervention will be borne 

entirely by the consumer.

3.

 If it is not possible to restore product conformity by repairing it, the product/component will be replaced, the guarantee expiration date and 

conditions will remain the same established when the product/component to be replaced has been purchased.

4.

 Extraflame S.p.A. cannot be held liable for injury or damage which may - either directly or indirectly - be caused to persons, animals 

and property ensuing from failure to observe all the instructions provided in the relevant instruction manual and the warnings regarding 

installation, use and maintenance of the product, that can also be downloaded on the website.

5.

 Interventions for adjusting and/or regulating the product for the type of fuel or other reasons are excluded by the guarantee.

6.

 If the product is repaired in one of the Authorised Technical Assistance Centres indicated by Extraflame S.p.A. and if the product is replaced, 

transport will be free of charge. If the technician can repair the product at the user's place of residence and they refuse, transport to the 

workshop and redelivery will be paid by the consumer.

7.

 

After the 24 months of the guarantee have elapsed any repair intervention cost will be completely borne by the consumer.

8.

 In the case of disputes the only competent court is that of the Extraflame S.p.A. registered office - (Vicenza-Italy) 

GUARANTEE TERMS 

Содержание LUISELLA

Страница 1: ...MADE IN ITALY design production LUISELLA 004276847 REV001 UK pellet stoves USER MANUAL...

Страница 2: ...2 ENGLISH...

Страница 3: ...2 stBY STAND BY 22 OPERATION with supplementary thermostat optional 22 DELT Delta T 22 res reset 23 Additional functions 23 FIRST LOAD 23 DELAY SWITCH OFF 23 Supplementary thermostat INSTALLATION opti...

Страница 4: ...ne faire tres attention aux composants en detail WARNUNG Bei der Handhabung der Maschine beachten Sie die Komponenten im Detail ATENCION Durante el desplazamiento de la ma quina tener mucho cuidado a...

Страница 5: ...OF AGE OR OLDER AND INDIVIDUALS WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPACITIES OR WITHOUT EXPERIENCE OR THE NECESSARY KNOWLEDGE PROVIDED THAT THEY ARE SUPERVISED OR HAVE RECEIVED INSTRUCTIONS ON...

Страница 6: ...aste Do not use any flammable liquids for ignition During the filling phase do not put the bag of pellets to into contact with the product The majolicas aretop quality artisan products and as such can...

Страница 7: ...that the documentation has been provided and must keep it with a copy of the technical documentation relating to the installation For installation in a condominium prior approval from the condominium...

Страница 8: ...e base of the vertical section If the exhaust is not inserted in an existing flue a vertical section with a windproof end piece is required UNI 10683 The vertical duct can be inside or outside the bui...

Страница 9: ...j k d D Details of luisella A Access to combustion chamber E Pellet hopper pressurised closure I Combustive air input B Display F Room air outlet j Serial input C Spacer G Upper fumes exhaust K On Off...

Страница 10: ...of the machine which determine the minimum distance any support behind the stove The spacers must not be removed Fuse If there is no power supply to the stove check the state of the fuse located in th...

Страница 11: ...ans that you have 60 to close the hatch door and the pellet lid After 60 seconds when the stove ignites it will go to DEPR ALARM mode while during normal operation the stove will go to COOLING STAND B...

Страница 12: ...hs of seasoning the calorific value of pellets is 5 kWh kg Pellet density is 650kg m3 and the water content is equal to 8 of its weight For this reason they do not require seasoning in order to arrive...

Страница 13: ...Indicates the set temperature status LED on the stove is reaching the set temperature room temperature still lower than set temperature LED off the stove has reached the set temperature Indicates comm...

Страница 14: ...st be loaded with pellets The combustion chamber must be clean The burn pot must be completely free and clean Check the hermetic closure of the hoper fire door and ash drawer Check that the power cabl...

Страница 15: ...2 Power increase Increases operating power 3 Power decrease Decreases operating power 4 T increase Increases the set thermostat 5 T decrease Decreases the set thermostat J Ifthe remote control is swit...

Страница 16: ...d key 4 Press key 3 until SET appears and access with key 4 Press key 3 until DAY appears and access with key 4 Set the day using keys 4 and 5 and confirm with key 2 Press key 1 several times to exit...

Страница 17: ...inimum value If the contact is open request the stove works at the set power If the setting is on HOT set above 40 C the stove only works at the set power thus bypassing the external contact and the t...

Страница 18: ...the calibration of the volumetric weight of the pellet go from the factory value 0 to 1 2 3 as required Controls procedure Press and hold key 4 Press key 3 until EASY appears and access with key 4 Adj...

Страница 19: ...ratures and power without influencing the stove work status NB if overlapping time slots are set the stove will stay on until the latest switch off time prg 1 4 PROGRAMMING 1 4 Prg x allows you to set...

Страница 20: ...23 50 PRG2 start time Stop OFF 00 00 23 50 PRG2 stop time DAY1 DAY7 On off Enabling disabling days for PRG2 TEMP LOU 07 40 C HOT Set thermostat PRG2 Pow 1 5 Set power PRG2 prg3 ABIL On Off Enables dis...

Страница 21: ...3 1 02 00 23 00 08 00 16 30 t 22 18 2 1 21 ENGLISH Time slot 1 start 02 00 stop 23 00 power 3 set temp 22 C Time slot 2 start 08 00 stop 16 30 power 1 set temp 18 C stove operation Time slot Power Set...

Страница 22: ...with supplementary thermostat optional STBY function set to OFF FACTORY DEFAULT SETTING In the even the Stand by function is not activated OFF if the stove reaches the room temperature set on the sup...

Страница 23: ...o1h thestovewillautomatically switch off at 9 pm If you press and hold keys 2 4 at the same time the screen DELAY SWITCH OFF will appear alternating with the countdown this setting can only be configu...

Страница 24: ...water or water and neutral soap Failure to comply with the indications can damage the surfaces of the generator and cause the warranty to become null and void Cleaning the ceramic glass Never use abra...

Страница 25: ...ant compartment Vacuum the ash from the burn pot slot ignition plug pipe holder and combustion chamber Unblock all the holes in the burn pot using the poker supplied Re position the burn pot in its sl...

Страница 26: ...lder and combustion chamber Unblock all the holes in the burn pot using the poker supplied Release the central wall of the fireplace from the clamps by sliding it upwards B Remove the cast iron wall b...

Страница 27: ...urn pot partition A where combustion takes place physically and a flame guard B When cleaning and removing the burn pot remove the flame guard B by lifting it Perform the same operation in reverse ord...

Страница 28: ...warranty GASKETS pellet hopper lid DOOR ASH DRAWER AND BURN POT The gaskets guarantee the tightness of the stove and its consequent good functioning They must be controlled periodically They must be...

Страница 29: ...licone or gasket in the points indicated B Gaskets pellet hopper and door replace them and apply silicone where required C Combustion chamber and heat exchanger full cleaning including ignition plug p...

Страница 30: ...he points indicated B Gaskets pellet hopper and door replace them and apply silicone where required C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete...

Страница 31: ...n indicates the presence of an alarm The alarm can only be reset if the fumes motor has stopped and 15 minutes have passed since the alarm was displayed by pressing key 1 for 3 seconds E00 Fumes motor...

Страница 32: ...bility to use the product and wrong maintenance by the consumer with respect to what is reported and recommended by the instructions manual of the product which is part of the sales contract this guar...

Страница 33: ...tlet pipes etc Please therefore avoid coming into contact with these parts without wearing suitable protective clothing or using appropriate measures such as heat protective gloves DO NOT use the prod...

Страница 34: ...34 ENGLISH...

Страница 35: ...35 ENGLISH...

Страница 36: ...ame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufacturer reserves the right to vary the chara...

Отзывы: