ENGLISH
every 30 days
Cleaning "T" fitting with inspection cap outside the stove: check and clean at least once a month
every 30 days
Cleaning the tube heat exChanger
Vacuum the residue in the burn pot
Remove the burn pot completely from the relevant
compartment (A);
Vacuum the ash from the burn pot slot, ignition plug pipe
holder and combustion chamber.
Unblock all the holes in the burn pot using the poker supplied.
Release the central wall of the fireplace from the clamps, by
sliding it upwards (B).
Remove the cast-iron wall by tilting it (C).
Once the central cast iron wall has been removed, clean the
tube heat exchanger (D).
After cleaning, replace the cast iron fire wall and reposition the burn
pot in its slot pushing it towards the fire wall.
NOTE: Use a suitable ash vacuum cleaner with a specific container
for separation of the ash collected.
a
b
C
d