iGniTion
Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove. There are 15 minutes available to
detect the presence of the flame during the ignition phase. When the control temperature is reached, stove interrupts the ignition phase and
switches to PREPARATION.
preparaTion
During the preparation phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and switch to WORK
work
In the work phase, the stove switches to the Set Power defined by the user, heating the room until Set Thermostat is achieved. See next
heading.
seT ThermosTaT
The Set room thermostat can be set with keys 4 and 5, from LOU - 7°C - 40°C - HOT. If the value is between 07°C-40°C, the stove controls the
room temperature by means of an on-board probe. Once the set temperature has been reached, the stove automatically decreases the power,
ensuring the best comfort and reducing pellet consumption. This process is called “modulation”.
lou - hoT
If the Set Thermostat is "LOU" (set under the 7° threshold), temperature control passes to the additional thermostat contact, thus bypassing
the on-board temperature probe.
If the contact is closed (fulfilled), the stove decreases to minimum value.
If the contact is open (request), the stove works at the set power.
If the setting is on “HOT” (set above 40°C), the stove only works at the set power, thus bypassing the external contact and the temperature
probe.
seT power
Set Power has 5 operating levels. The power can be changed with keys 2 or 3.
Power 1 = minimum level - Power 5 = maximum level.
Press key 1 to exit and save the change.
auTo Blow
During the work phase, the stove cleans the burn pot at regular intervals with an "AUTO BLOW".
When this procedure starts, a message is displayed. During the "AUTO BLOW" procedure, the pellet feed slow down and the fumes motor
increases.
After cleaning, the stove resumes working at normal operational conditions.
swiTch-off
Press key 1 for three seconds.
Once this operation has been performed, the appliance automatically enters the switch-off phase, blocking the supply of pellets.
The flue gas exhaust motor and the hot air flow motor will remain on until the stove temperature has dropped below the safety settings.
re-iGniTion
The stove can only be re-ignited if the temperature of the exhaust fumes is lower than the pre-set threshold and the minimum safety time has
passed.
operaTion anD loGic
Do noT use any Type of flammaBle liquiDs for iGniTion!
Do noT allow The BaG of pelleTs To come inTo conTacT wiTh The BoilinG hoT sTove DurinG The
fillinG phase!
in The evenT of conTinueD failure To liGhT, conTacT an auThoriseD Technician.