22
ENGLISH
sTBy (sTanD-By)
The stand-by function is used if the stove needs to be turned off immediately instead of a power modulation.
CONTROLS PROCEDURE
Press and hold key 4.
Press key 3 until
SET
appears and access with key 4.
Press key 3 until
STBY
appears and access with key 4.
Enable/disable using keys 4 and 5 and confirm with key 2.
Press key 1 several times to exit the menu.
daTE
daY
TimE
Lng
C-f
SEE CHAPTER: COMMISSIONING SETTINGS.
J
for CorrECT opEraTion, SET ThErmoSTaT ShoULd BE SET in LoU.
> SEE ThE inSTaLLaTion ChapTEr SUppLEmEnTarY ThErmoSTaT
seT (seTTinGs)
sTBy funcTion seT To on
When the Stand-by function is active (ON), if the room temperature exceeds the
SET ThErmoSTaT
value +
dELT
, the stove will switch off
after a pre-set (default) delay period, displaying
STBY
.
When the room temperature is lower than the
SET ThErmoSTaT
-
dELT
, the stove cools down, if necessary, and then switches off.
sTBy funcTion seT To off (facTory DefaulT seTTinG)
In the event the Stand-by function is not activated (OFF), if the stove exceeds the set room temperature, it will switch to the minimum power
level, modulating and displaying
modULaTion
. When the room temperature is lower than the
SET ThErmoSTaT
the stove will restart at
the set power and
Work
will be displayed on the screen.
operaTion wiTh supplemenTary ThermosTaT (opTional)
sTBy funcTion seT To off
FACTORY DEFAULT SETTING)
In the even the Stand-by function is not activated (OFF), if the stove reaches the room temperature set on the supplementary thermostat
(closed contact), it will switch to the minimum power level and display MODULATION. When the room temperature is lower than the set value
on the supplementary thermostat (open contact), the stove will restart at the set power, and WORK will be displayed on the screen.
sTBy funcTion seT To on
If the STAND-BY function is activated (ON), when the room temperature set on the supplementary thermostat is reached (closed contact), the
stove will switch off after a pre-set (default) delay period, and
STBY
will be displayed on the screen.
When the room temperature is lower than the supplementary thermostat (open contact), the stove cools down, if necessary, and then re-
ignites.
DelT (DelTa-T)
This function allows you to set the delta-t for igniting and switching off the stove
,
used as a room temperature adjustment interval if there
is no external thermostat. The exact temperature for ignition is
SET ThErmoSTaT
- Delta-T
.
The temperature for switching off is
SET
ThErmoSTaT
+
Delta-T
.
The possible values for Delta-T range from:
0.5 - 5°C
CONTROLS PROCEDURE
Press and hold key 4.
Press key 3 until
SET
appears and access with key 4.
Press key 3 until
dELT
appears and access with key 4.
Adjust with keys 4-5 and 2 to confirm.
Press key one several times to confirm and exit the menu.