ENGLISH
Displays
Display
Reason
off
Generator off
sTaRT
The start-up phase is in progress
pelleT loaDinG
Continuous pellet feeding is in progress during the ignition phase
iGniTion
The ignition phase is in progress
pRepaRaTion
The preparation phase is in progress
WoRk
The normal work phase is in progress
MoDulaTion
The generator is working at minimum
final cleaninG
The final cleaning is in progress
sTanD-by
Generator off waiting for re-ignition due to the external thermostat.
coolinG sTanD by
A new ignition is attempted when the generator has just been switched off. When the generator switches off, you must
wait for the complete shutdown of the fumes motor, then clean the burn pot. The generator can only be re-ignited when
these operations have been performed.
black ouT sTanD
by
The generator is cooling after a power cut.
Once cooling is completed, it will re-start automatically
auTo bloW
The automatic blow is active
seRvice
When this message appears, contact the technician authorised to perform routine maintenance on the stove. If the
cleaning is not performed, the message will appear at every start-up but without interrupting the normal operation of
the stove.
alaRMs
Display
eXplanaTion
soluTion
Indicates the presence of an alarm.
On: indicates the presence of an alarm.
The alarm can only be reset if the fumes motor has stopped and 15
minutes have passed since the alarm was displayed, by pressing key 1
for 3 seconds.
e00
Fumes motor fault
Contact after-sales centre
e01
Fumes probe fault.
Contact after-sales centre
e02
High fumes temperature
Check pellet feed (see “Easy”), if the problem cannot be solved, contact
an authorised technician.
e03
NO IGNITION
The pellet hopper is empty.
Pellet feed calibration inadequate.
Thermostat bulbs tripped.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see “Easy”).
Check the procedures described in the “Ignition” chapter.
Check the thermostats with bulbs (see chapter on Resetting)
e04
NO FLAME
The pellet hopper is empty.
No pellet feed.
The gearmotor does not feed pellets.
Check for the presence of pellets in the hopper.
Adjust the pellet flow (see “Easy”).
e05
DEPR ALARM
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The fumes exhaust pipe is blocked/dirty.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
e06
NO IGNITION BLACK OUT
No current during the ignition phase.
Turn the stove off using key 1 and repeat the procedure described in
the "Ignition" chapter.
Other reset operations should be performed by an authorised
technician.
e07
Triac
Abnormal pellet loading.
Contact after-sales centre