37
CLEANING
Chapter10
Once the heat exchanger chamber is accessible, use
the ash hook to remove the deposited residues and
scrape off any encrustation. Finally use a vacuum
cleaner to complete the cleaning (fi gure 11.7). After
that, proceed in reverse order to reposition the pull-
out cast iron. Once the furnace wall is in position,
rotate the door latch by 180° to return it to its original
position.
DOOR, ASH DRAWER AND BRAZIER SEALS
The seals ensure that the stove is hermetically sealed and consequently that it operates correctly.
The seals should be checked periodically and replaced immediately if worn or damaged.
These operations must be carried out by an authorised technician.
To ensure correct operation, the stove should have general maintenance performed at
least once a year by an authorised technician.
If the power cable is damaged, it must only be replaced by the service centre or by a qualifi ed technician,
in order to avoid any risks.
CHIMNEY CONNECTION
Once a year, or whenever needed, vacuum and clean the duct that leads to the chimney.
If there are horizontal sections, remove any ash residues before they can obstruct passage of the smoke.
FAILURE TO CLEAN jeopardises safety.