22
Chapter5
COMFORT MINI/P80/MINI CRYSTAL INSTALLATION
To ensure the correct and safe operation of the insert, when building the fi replace it is necessary to respect
the clearances between the insert and the inner walls of the fi replace.
Considering the measurements given in the technical specifi cations, you need to account for at least 50
mm of air space in the upper part and on the two sides.
The exhaust outlet pipe must always be at a minimum distance of 5 cm from flammable
parts.
Warm convection air
It is necessary provide an outlet for the
heat accumulated in the facing to prevent
excessive overheating of the insert.
Forced ventilation
The blower conveys the heat produced in
the insert into the room.
Air inlet from the room
To enable air circulation, it is necessary
to have an air inlet point, preferably at
the lower part of the structure, for better
convection. The air must be drawn from
the room where the stove is installed.
fi gure 5.16