installer Programmable Features (cont’d)

Feature #11   Remote Start Lock Control

Off

   

 

 

 

 

(press “

lock

” button to program)

 - DEFAULT

Lock After Start

  

 

 

(press “

unlock

” button to program)

Unlock before start

   

 

(press “

trunk

” button to program)

Unlock Lock After Start 

(press “

start

” button to program)

This feature allows for OEM alarm/lock control in relation to remote start operations thus eliminat-

ing extra wiring�

Feature #12   Low Temp Crank Extender

0ms (Off)

  (press “

lock

” button to program)

200ms

 

(press “

unlock

” button to program)

 - DEFAULT

300ms

 

(press “

trunk

” button to program)

400ms

 

(press “

start

” button to program)

When the vehicle’s interior temperature is below freezing, this feature adds extra crank time to the 

base timing (see  installer feature #7)� It applies to tachless modes only (installer feature #6)

Feature #13   Data Port Protocol

ADS (iData) 

(press “

unlock

” button to program)

 

D2D (Trilogix)

  (press “

lock

” button to program) 

- DEFAULT

This feature determines which data protocol is used on both data ports� Choose this based on 

the accessory being connected to the port� 

nOTE: when a BLADE is inserted, this feature 

automatically switches to the ADS protocol.
Feature #14   Lock On Prewarn

On 

(press “

lock

” button to program)

 

 

- DEFAULT

Off

  (press “

unlock

” button to program)

By default, if the prewarn zone is triggered, the system will automatically lock the doors to combat 

unauthorized entry from lock picking. If this causes conflict with OEM vehicle functions, you can 

turn it off�

Feature #15   Blue Satellite Port, Blue wire Function

Status

 

 

 

 

(press “

lock

” button to program)

 - DEFAULT

Pulse Before Start

 

 

(press “

unlock

” button to program)

Pulse After Start

 

 

(press “

trunk

” button to program)

Pulse After Engine Off

 

(press “

start

” button to program)

This determines the function of the Blue wire on the Blue satellite relay port�

The Status setting turns on briefly before the Ignition output and stays on during remote start 

mode� The other settings give a 0�8 second pulse under the selected condition�

Feature #16   Low Current / motorcycle mode

On 

(press “

lock

” button to program)

 

 

Off

  (press “

unlock

” button to program) 

- DEFAULT

This feature, when on, reduces the system’s current draw by as much as 40% to maximize the 

vehicle’s battery life while the alarm is armed� It causes the starter interrupt output to only oper-

ate when the ignition is turned on and reduces the frequency of the “armed” flashing status light 

significantly. This is ideal when the system is to be used on vehicles that have limited battery 

capacity and/or may sit for extended periods without charging the battery�

Содержание AL-1650-EDPB

Страница 1: ...AL 1650 EDPB AL 1750 EDPB Deluxe Alarm Remote Start July 11 2012 Operation Guide Temporary cover Color cover is in a separate file...

Страница 2: ...rjacking Protection 10 Programming Transmitters 11 Programming Features 12 User Programmable Features 12 Installer Programmable Features 15 Programmable Features Matrix 19 This device complies with FC...

Страница 3: ...utton the siren will chirp twice the parking lights will flash twice then illuminate for 30 seconds AL 1650 EDPB part number 147 03 AL 1750 EDPB part number 1410 03 Call your dealer or visit www caral...

Страница 4: ...ired when you use the remote start The engine will run for the preset run time see user feature 18 Run Time Extender Press the START button one time during remote start to restart the engine run timer...

Страница 5: ...ds The siren horn will sound the park ing lights will flash and the doors will lock or unlock depending which button is pressed OR SILENT ARM DISARM Press and release the TRUNK button twice in 5 secon...

Страница 6: ...TRUNK button within 5 seconds of locking arming the alarm system the system will give one chirp to indicate the sensor is bypassed Low Battery Low Temp Automatic Starting Other Remote Start Features...

Страница 7: ...sed the system will keep the engine running for the programmed time 1 2 or 3 minutes and then automatically turn it off The system may be locked while the engine is running Turbo Timer can be prevente...

Страница 8: ...before rearming the pre warn zone Additionally if a full trigger zone is left open the system will trigger a total of 3 times before bypassing the zone Once the zone is closed again it will re arm th...

Страница 9: ...larm will activate STEP 2 Turn the ignition switch to the ON position STEP 3 Within 5 seconds of step 2 press the valet switch to enter the first digit of your programmed code STEP 4 After a few secon...

Страница 10: ...ion reflect combinations of functions involving the security system AND remote start SLOWLY ALTERNATES GREEN RED System is in full valet mode SOLID GREEN W RED FLASH System is in remote start valet w...

Страница 11: ...n Special Programming procedure to turn on the UTA feature Using this method to program transmitters or optional controllers and to turn on the Unauthorized Trans mitter Alert feature Follow the same...

Страница 12: ...be required in order to perform an Emergency Override If any of the three anti carjacking features are utilized a customized SecureCode would also be required to turn it off once it is fully activate...

Страница 13: ...rter Interrupt output to automatically engage 90 seconds after the ignition switch is turned off and after disarming the system Feature 7 Open Door Bypass of Ignition Locking On press lock button to p...

Страница 14: ...iolation citation Feature 11 Flashing Light Confirmations On w Disarm Flash w RS press unlock button to program DEFAULT On w Disarm Remote Start press lock button to program On During Remote Start pre...

Страница 15: ...utton to program This feature changes how the remote start feature is activated using the controller or transmitter Feature 18 Remote Start Run Time 10 Minutes press unlock button to program DEFAULT 5...

Страница 16: ...nual Transmission Mode Off press unlock button to program DEFAULT On press lock button to program This feature changes the parameters of the system s remote start operation to be suitable for manual t...

Страница 17: ...try up to 3 more times extending the crank time by an additional 0 2 second with each attempt Feature 9 Arm Disarm or Additional Channels Arm Disarm press lock button to program DEFAULT Arm Channel 5...

Страница 18: ...press lock button to program DEFAULT Off press unlock button to program By default if the prewarn zone is triggered the system will automatically lock the doors to combat unauthorized entry from lock...

Страница 19: ...ng Upon Arm On Off 17 Remote Start Activation Start x 2 Start x 1 Lock Unlock 18 Remote Start Run Time 5 min 10 min 15 min 20 min Installer Feature Programming Ignition on off press valet 10 times 1 D...

Страница 20: ...Back Cover Color cover is in a separate file...

Отзывы: