Excalibur AL-1650-EDPB Скачать руководство пользователя страница 15

15

User Programmable Features (cont’d)

Feature #14 - Alarm Functions Bypass 

Off      

(press “

unlock

” button to program)

 - DEFAULT

On      

(press “

lock

” button to program)

 

 

This feature converts the system into a strictly Keyless Entry/Remote Start System by 

eliminating all antitheft alarm-oriented operations and features�  

Feature #15 - Anti-Carjacking

Off              

(press “

start

” button to program)

 - DEFAULT

ignition Only   

(press “

lock

” button to program) 

Door Only 

    (press “

unlock

” button to program)

ig Door  

(press “

trunk

” button  to program)

 

This selects between the 2 forms of anti-carjacking protection�  Details on using anti-

carjacking protection are described on page 10�

Feature #16 - Open Door warning Upon Arming

Off      

(press “

unlock

” button to program)

 - DEFAULT

On      

(press “

lock

” button to program)

When this feature is turned on, if one of the vehicle’s doors is open at the time that 

the system is armed via the controller or transmitter, the siren  will chirp 3 times and 

the parking lights will flash 3 times instead of once.

Feature #17 - Remote Start Activation

Press 

start

” 

button 2 times

    (press “

lock

” button to program)

 - DEFAULT

Press 

start

” 

button 1 time

    (press “

unlock

” button  to program)

 

Press Lock & Unlock        

(press “

trunk

” button to program)

This feature changes how the remote start feature is activated using the controller or 

transmitter�

Feature #18 - Remote Start Run Time

10 minutes   

(press “

unlock

” button to program)

 - DEFAULT

5 minutes   

(press “

lock

” button to program)

 

15 minutes   

(press “

trunk

” button to program)

20 minutes   

(press “

start

” to program)

This feature sets the period of time that the engine will run when remote started� If the 

engine is not stopped by controller/transmitter command or a safety circuit violation, 

the engine will automatically stop upon the expiration of the selected time period�

installer Programmable Features

This group of Installer Programmable Features are all accessed as a group in the second level of 

features’ programming�  These features have a direct affect upon the system’s operations related 

to the installation and vehicle type 

AnD ShOULD OnLY BE ChAnGED BY ThE inSTALLER!!!

Feature #1 - Doorlocking Functions     

0.8 Second Outputs

        (press “

lock

” button to program)

 - DEFAULT

3 Second Outputs         

(press “

unlock

” button to program)

Double Pulse Unlock Output 

(press “

trunk

” button to program)

Total Closure Lock Output  

(press “

start

” button to program)

This single feature gives the installer several needed options, to match the system’s doorlocking 

outputs to suite different vehicle requirements. The total closure setting provides a 28 second lock 

pulse and a 0�8 second unlock pulse�

Содержание AL-1650-EDPB

Страница 1: ...AL 1650 EDPB AL 1750 EDPB Deluxe Alarm Remote Start July 11 2012 Operation Guide Temporary cover Color cover is in a separate file...

Страница 2: ...rjacking Protection 10 Programming Transmitters 11 Programming Features 12 User Programmable Features 12 Installer Programmable Features 15 Programmable Features Matrix 19 This device complies with FC...

Страница 3: ...utton the siren will chirp twice the parking lights will flash twice then illuminate for 30 seconds AL 1650 EDPB part number 147 03 AL 1750 EDPB part number 1410 03 Call your dealer or visit www caral...

Страница 4: ...ired when you use the remote start The engine will run for the preset run time see user feature 18 Run Time Extender Press the START button one time during remote start to restart the engine run timer...

Страница 5: ...ds The siren horn will sound the park ing lights will flash and the doors will lock or unlock depending which button is pressed OR SILENT ARM DISARM Press and release the TRUNK button twice in 5 secon...

Страница 6: ...TRUNK button within 5 seconds of locking arming the alarm system the system will give one chirp to indicate the sensor is bypassed Low Battery Low Temp Automatic Starting Other Remote Start Features...

Страница 7: ...sed the system will keep the engine running for the programmed time 1 2 or 3 minutes and then automatically turn it off The system may be locked while the engine is running Turbo Timer can be prevente...

Страница 8: ...before rearming the pre warn zone Additionally if a full trigger zone is left open the system will trigger a total of 3 times before bypassing the zone Once the zone is closed again it will re arm th...

Страница 9: ...larm will activate STEP 2 Turn the ignition switch to the ON position STEP 3 Within 5 seconds of step 2 press the valet switch to enter the first digit of your programmed code STEP 4 After a few secon...

Страница 10: ...ion reflect combinations of functions involving the security system AND remote start SLOWLY ALTERNATES GREEN RED System is in full valet mode SOLID GREEN W RED FLASH System is in remote start valet w...

Страница 11: ...n Special Programming procedure to turn on the UTA feature Using this method to program transmitters or optional controllers and to turn on the Unauthorized Trans mitter Alert feature Follow the same...

Страница 12: ...be required in order to perform an Emergency Override If any of the three anti carjacking features are utilized a customized SecureCode would also be required to turn it off once it is fully activate...

Страница 13: ...rter Interrupt output to automatically engage 90 seconds after the ignition switch is turned off and after disarming the system Feature 7 Open Door Bypass of Ignition Locking On press lock button to p...

Страница 14: ...iolation citation Feature 11 Flashing Light Confirmations On w Disarm Flash w RS press unlock button to program DEFAULT On w Disarm Remote Start press lock button to program On During Remote Start pre...

Страница 15: ...utton to program This feature changes how the remote start feature is activated using the controller or transmitter Feature 18 Remote Start Run Time 10 Minutes press unlock button to program DEFAULT 5...

Страница 16: ...nual Transmission Mode Off press unlock button to program DEFAULT On press lock button to program This feature changes the parameters of the system s remote start operation to be suitable for manual t...

Страница 17: ...try up to 3 more times extending the crank time by an additional 0 2 second with each attempt Feature 9 Arm Disarm or Additional Channels Arm Disarm press lock button to program DEFAULT Arm Channel 5...

Страница 18: ...press lock button to program DEFAULT Off press unlock button to program By default if the prewarn zone is triggered the system will automatically lock the doors to combat unauthorized entry from lock...

Страница 19: ...ng Upon Arm On Off 17 Remote Start Activation Start x 2 Start x 1 Lock Unlock 18 Remote Start Run Time 5 min 10 min 15 min 20 min Installer Feature Programming Ignition on off press valet 10 times 1 D...

Страница 20: ...Back Cover Color cover is in a separate file...

Отзывы: