Excalibur AL-1650-EDPB Скачать руководство пользователя страница 16

16

installer Programmable Features (cont’d)

Feature #2 - Light Relay Functions     

Dome Light Output

  (press “

lock

” button to program)

 - DEFAULT

Door Lock        

(press “

unlock

” button to program)

ignition Output 

    (press “

trunk

” button to program)

Accessory Output  

(press “

start

” button to program)

The system has two built-in relays, which can be programmed to perform several different func-

tions�  The primary function of this relay, is to operate the vehicle’s dome, or interior lighting as 

part of the system’s operations�  Optionally, if desired or needed, this relay can be programmed to 

be a door lock relay, or as medium-capacity ignition or accessory outputs (10A max), if needed for 

remote starting use� 

Feature #6 - Engine Detection method

Tachless hi

 

(press “

lock

” button to program)

 - DEFAULT

Tachless Lo

 

(press “

unlock

” button to program)

Tach wire

        (press “

trunk

” button to program)

Data Tach

        (press “

start

” button to program) 

Crank Only

 

(press “

lock

” & “

unlock

” to program)

This feature selects the method in which the remote start monitors the engine’s running condition 

in remote start mode�  

“Tachless hi”

 sensitivity mode uses a preset crank time (see installer feature #7) and monitors 

the vehicle’s voltage level to determine if the engine is running� This setting looks for a voltage 

increase of 0�3v after cranking�  

“Tachless Lo”

 sensitivity mode operates like the “Tachless hi” setting but looks for a voltage  

     

increase of 0�5v after cranking�

Feature #5 - manual Transmission mode

Off      

(press “

unlock

” button to program)

 - DEFAULT

On      

(press “

lock

” button to program)

This feature changes the parameters of the system’s remote start operation to be suitable for 

manual transmission-equipped vehicles via a “setup” procedure which must be followed upon exit

-

ing the vehicle to ensure the transmission is in neutral�

Feature #4 - Turbo Timer

Off

          (press “

lock

” button to program)

 - DEFAULT

Run 1 minute  

(press “

unlock

” button to program)

Run 2 minutes

  (press “

trunk

” button to program)

Run 3 minutes 

(press “

start

” button to program)

This feature, the operation of which is described on page 9, when turned on 

configures the system to automatically keep the engine running briefly after it is turned off.  This 

operation is designed specifically for vehicles having turbocharged engines (the user may tempo

-

rarily bypass the feature if desired)� 

This feature should only be programmed by the installer

and the operation of this feature depends on the correct connection of the safety wire to the 

vehicle’s parking brake�   

Feature #3 - horn Relay Functions

horn Output

        (press “

lock

” button to program)

 - DEFAULT

Door Unlock       

(press “

unlock

” button to program)

Trunk Release   

  (press “

trunk

” button to program)

Pulse After Start   

(press “

start

” button to program)

The primary function of this second relay, is to operate the vehicle’s existing horn; either in 

conjunction with the electronic siren, or in place of the siren�  Using both the siren and the horn 

creates an extremely effective security system� Optionally, if desired or needed, this relay can be 

programmed as a door unlock, trunk release, or pulse after start relay�

Содержание AL-1650-EDPB

Страница 1: ...AL 1650 EDPB AL 1750 EDPB Deluxe Alarm Remote Start July 11 2012 Operation Guide Temporary cover Color cover is in a separate file...

Страница 2: ...rjacking Protection 10 Programming Transmitters 11 Programming Features 12 User Programmable Features 12 Installer Programmable Features 15 Programmable Features Matrix 19 This device complies with FC...

Страница 3: ...utton the siren will chirp twice the parking lights will flash twice then illuminate for 30 seconds AL 1650 EDPB part number 147 03 AL 1750 EDPB part number 1410 03 Call your dealer or visit www caral...

Страница 4: ...ired when you use the remote start The engine will run for the preset run time see user feature 18 Run Time Extender Press the START button one time during remote start to restart the engine run timer...

Страница 5: ...ds The siren horn will sound the park ing lights will flash and the doors will lock or unlock depending which button is pressed OR SILENT ARM DISARM Press and release the TRUNK button twice in 5 secon...

Страница 6: ...TRUNK button within 5 seconds of locking arming the alarm system the system will give one chirp to indicate the sensor is bypassed Low Battery Low Temp Automatic Starting Other Remote Start Features...

Страница 7: ...sed the system will keep the engine running for the programmed time 1 2 or 3 minutes and then automatically turn it off The system may be locked while the engine is running Turbo Timer can be prevente...

Страница 8: ...before rearming the pre warn zone Additionally if a full trigger zone is left open the system will trigger a total of 3 times before bypassing the zone Once the zone is closed again it will re arm th...

Страница 9: ...larm will activate STEP 2 Turn the ignition switch to the ON position STEP 3 Within 5 seconds of step 2 press the valet switch to enter the first digit of your programmed code STEP 4 After a few secon...

Страница 10: ...ion reflect combinations of functions involving the security system AND remote start SLOWLY ALTERNATES GREEN RED System is in full valet mode SOLID GREEN W RED FLASH System is in remote start valet w...

Страница 11: ...n Special Programming procedure to turn on the UTA feature Using this method to program transmitters or optional controllers and to turn on the Unauthorized Trans mitter Alert feature Follow the same...

Страница 12: ...be required in order to perform an Emergency Override If any of the three anti carjacking features are utilized a customized SecureCode would also be required to turn it off once it is fully activate...

Страница 13: ...rter Interrupt output to automatically engage 90 seconds after the ignition switch is turned off and after disarming the system Feature 7 Open Door Bypass of Ignition Locking On press lock button to p...

Страница 14: ...iolation citation Feature 11 Flashing Light Confirmations On w Disarm Flash w RS press unlock button to program DEFAULT On w Disarm Remote Start press lock button to program On During Remote Start pre...

Страница 15: ...utton to program This feature changes how the remote start feature is activated using the controller or transmitter Feature 18 Remote Start Run Time 10 Minutes press unlock button to program DEFAULT 5...

Страница 16: ...nual Transmission Mode Off press unlock button to program DEFAULT On press lock button to program This feature changes the parameters of the system s remote start operation to be suitable for manual t...

Страница 17: ...try up to 3 more times extending the crank time by an additional 0 2 second with each attempt Feature 9 Arm Disarm or Additional Channels Arm Disarm press lock button to program DEFAULT Arm Channel 5...

Страница 18: ...press lock button to program DEFAULT Off press unlock button to program By default if the prewarn zone is triggered the system will automatically lock the doors to combat unauthorized entry from lock...

Страница 19: ...ng Upon Arm On Off 17 Remote Start Activation Start x 2 Start x 1 Lock Unlock 18 Remote Start Run Time 5 min 10 min 15 min 20 min Installer Feature Programming Ignition on off press valet 10 times 1 D...

Страница 20: ...Back Cover Color cover is in a separate file...