16
installer Programmable Features (cont’d)
Feature #2 - Light Relay Functions
Dome Light Output
(press “
lock
” button to program)
- DEFAULT
Door Lock
(press “
unlock
” button to program)
ignition Output
(press “
trunk
” button to program)
Accessory Output
(press “
start
” button to program)
The system has two built-in relays, which can be programmed to perform several different func-
tions� The primary function of this relay, is to operate the vehicle’s dome, or interior lighting as
part of the system’s operations� Optionally, if desired or needed, this relay can be programmed to
be a door lock relay, or as medium-capacity ignition or accessory outputs (10A max), if needed for
remote starting use�
Feature #6 - Engine Detection method
Tachless hi
(press “
lock
” button to program)
- DEFAULT
Tachless Lo
(press “
unlock
” button to program)
Tach wire
(press “
trunk
” button to program)
Data Tach
(press “
start
” button to program)
Crank Only
(press “
lock
” & “
unlock
” to program)
This feature selects the method in which the remote start monitors the engine’s running condition
in remote start mode�
“Tachless hi”
sensitivity mode uses a preset crank time (see installer feature #7) and monitors
the vehicle’s voltage level to determine if the engine is running� This setting looks for a voltage
increase of 0�3v after cranking�
“Tachless Lo”
sensitivity mode operates like the “Tachless hi” setting but looks for a voltage
increase of 0�5v after cranking�
Feature #5 - manual Transmission mode
Off
(press “
unlock
” button to program)
- DEFAULT
On
(press “
lock
” button to program)
This feature changes the parameters of the system’s remote start operation to be suitable for
manual transmission-equipped vehicles via a “setup” procedure which must be followed upon exit
-
ing the vehicle to ensure the transmission is in neutral�
Feature #4 - Turbo Timer
Off
(press “
lock
” button to program)
- DEFAULT
Run 1 minute
(press “
unlock
” button to program)
Run 2 minutes
(press “
trunk
” button to program)
Run 3 minutes
(press “
start
” button to program)
This feature, the operation of which is described on page 9, when turned on
configures the system to automatically keep the engine running briefly after it is turned off. This
operation is designed specifically for vehicles having turbocharged engines (the user may tempo
-
rarily bypass the feature if desired)�
This feature should only be programmed by the installer
,
and the operation of this feature depends on the correct connection of the safety wire to the
vehicle’s parking brake�
Feature #3 - horn Relay Functions
horn Output
(press “
lock
” button to program)
- DEFAULT
Door Unlock
(press “
unlock
” button to program)
Trunk Release
(press “
trunk
” button to program)
Pulse After Start
(press “
start
” button to program)
The primary function of this second relay, is to operate the vehicle’s existing horn; either in
conjunction with the electronic siren, or in place of the siren� Using both the siren and the horn
creates an extremely effective security system� Optionally, if desired or needed, this relay can be
programmed as a door unlock, trunk release, or pulse after start relay�