background image

Options:
Panic

(

press

 

disarm/unlock” button  to program

)

4th Channel

(

press “

II

” button to program

)

5th Channel

(

press

 

III

” button  to program

)

This feature changes how the controller’s or transmitter’s “

III

” button operates.

Normal operation, or the default setting, has the “

III

” button operate the 3rd Channel

output (press the button twice within 5 seconds).  This feature allows changing it to
instead operate panic or either of the two other optional channel outputs (see the
Complete Programmable Features Matrix on page 33).  Panic can always be
operated, by the alternative methods of pressing either the “arm/lock” and “disarm/
unlock
” button for 3 seconds.

Page - 30

Feature #22   Doorlocking Functions

Factory Default Setting

.8 Second Lock & Unlock Output
(

press

 

arm/lock” button to program

)

Options:
3 Second Lock & Unlock Output     
(

press

 

disarm/unlock” button to program

)

Double Pulse Unlock Output

(

press

 

II

” button to program

)

Total Closure Lock Output

(

press

 

III

” button to program

)

This single feature gives the installer several needed options, to match the security
system’s doorlocking outputs to suite different vehicle requirements.

The first setting (programmed by the “arm/lock” button) has the system
produce both the lock and unlock outputs as .8 second in duration.  This is the
most common form of output needed, which interfaces most vehicles.

The second setting (programmed by the “disarm/unlock” button) changes the
lock and unlock outputs to be a longer 3 second pulse output.  This is for certain
vehicles which require a longer output pulse from the system’s control unit;
typically cars having vacuum pump systems, although the longer setting is also
more suitable in some newer vehicles.

Some newer vehicles require a double pulse output to remotely unlock the doors
and/or to disarm a factory-equipped security system, which is what the Double
Pulse Unlock setting provides (it is programmed by the “

II

” button ).  The lock

output pulse, in this setting, is .8 second.

The Total Closure Lock Output (programmed by the “

III

” button) may be used

with vehicles which are originally equipped with the total-closure feature.
Typically, a total closure feature is when locking the vehicle’s doors if the key
in the door is held to “lock” for a period of time the vehicle will close all
windows and the sunroof, in addition to locking the doors.
Selecting this feature setting changes the system’s door lock output pulse from
a .8 second to as long as a 28 second duration output.  The unlock output is 3
seconds in this setting.

Note:

 When this feature is turned on, during the 28 second period after arm-

ing the system, the lock output can be stopped on demand by the user by

the ignition switch, the supply wire behind the fuse block or the fuse/junction block.
Never just insert the Red wire or any other security system wire behind a fuse.  Also,
please note that connecting directly to the battery's Positive terminal will expose this
connection to failure due to a corrosive environment unless the connection has a
protective coating.

Yellow Wire - (Ignition Input): 

   

The Yellow wire is an ignition "on"

input to the security system.  This connection is critical to the proper operation of
many of the security system's features.

CONNECTION:

 This wire supplies Positive 12 Volts to the control module

whenever the ignition switch is "on".  This connection should be made at the ignition
switch harness, to the primary ignition circuit.  Primary ignition has 0 Volts when
the ignition key is in the  "Lock", "Off" and "Accessory" positions; and Positive 12
Volts in the "Run" and "Start" positions.  Locate the correct wire at the ignition
switch harness and securely splice the Yellow wire to it.

Orange Wire - (Negative Output While Armed); Includes the

thick Red & White Wires attached to the relay socket - (Starter
Interrupt):

  The Orange wire is a starter interrupt output, which is active when

the security system is in an armed state; the relay that it is attached to the Orange wire
prevents the starter from engaging, if a starting attempt is made while the system is
armed.

CONNECTION: 

 The typical starter interrupt is shown here-

Page - 7

Dash-

mounted

Ignition

Switch

Relay

  Starter Disable White
 wire to the
Starter Solenoid
side of the cut
wire.

Starter
Solenoid

Starter

Motor

Starter Disable Red
wire to the Ignition
 Switch side of the
         cut wire.

Starter

Disable

Socket

5-Pin

Connector

Socket

Orange

wire

Excalibur

Control

Module

Starter Disable
Connections

Содержание AL-1010-EDP

Страница 1: ...is to be printed with gray scale front cover this is a place marker cover Excalibur INSTALLATION INSTRUCTIONS COPYRIGHT 2009 OMEGA RESEARCH DEVELOPMENT INC FRONT COVER PRINTER S NOTE production front...

Страница 2: ...ansceiver or Coaxial Antenna 22 Programming The Programmable Features 23 31 Programming Features 32 Programmable Features Matrix 33 Contents Omega Disclaims Any Responsibility or Liability In Connecti...

Страница 3: ...le which is mounted upon completion of the installation and testing of the system Some of the wiring connections such as power ignition and starter interrupt are best made at the ignition switch harne...

Страница 4: ...the vehicle Separate AL 1010 EDP In the case of the AL 1010 EDP or as optional parts for the AL 1510 EDP the separate Status Light and Valet Switch may be custom mounted inside the vehicle For the Sta...

Страница 5: ...ystems and accept all Omega analog doorlocking accessories dual triple relay sockets or the modular clip on add on relay packs All Omega doorlocking data bus module accessories can be driven by this p...

Страница 6: ...und is difficult to diagnose pressing the arm lock or disarm unlock button Only the output itself will stop pressing either button again will normally operate the system and at any time after the 28 s...

Страница 7: ...ure Typically a total closure feature is when locking the vehicle s doors if the key in the door is held to lock for a period of time the vehicle will close all windows and the sunroof in addition to...

Страница 8: ...s will flash 3 times instead of once Feature 17 Ignition Activated Anti Carjacking Protection Feature 21 III Button Operation Factory Default Setting 3rd Channel press arm lock button to program Thest...

Страница 9: ...tion andnot the interior light operation Page 9 Secondary Wiring Harness 8 Wire Connector Brown Wire Positive Siren Output The Brown wire is a 1 Amp Positive output designed to operate the electronic...

Страница 10: ...them for disarming confirmation to confirm remote starting and to attract attention while the system is activated CONNECTION Connect this wire to the vehicle s Positive 12 Volt parking light circuit...

Страница 11: ...nition switch is turned on An exception to this would be if feature 8 is turned on and a door being open when the ignition switch is turned on The following feature 7 controls the automatic unlocking...

Страница 12: ...12 The correct wire for a Positive switching type of dome light door jamb pin switch system will have 12 volts present when the doors are opened and chassis ground when the doors are closed CONNECTION...

Страница 13: ...and closes the door This feature turns that operation on or off and with options of having Last Door Arming operate with or without also locking the doors when the system does arm SecureCode is a uni...

Страница 14: ...3 Disarm Alarm Upon Trunk Release 14 Arming Delay 15 Steady Siren Output Pulsed Horn 16 Alarm Functions Bypass 17 Ignition Activated Anti Carjacking Protection 18 Door Activated Anti Carjacking Protec...

Страница 15: ...he exposed inner end high in the dash or behind pillar trim for the best operating range Do not place the exposed end too close to metal structural parts of the vehicle The AL 1010 EDP can be upgraded...

Страница 16: ...tch s wiring Page 21 The two later wires are both routed to the doorlock actuators and are connected to either end of the actuator s motor winding When the switch is pushed to one position one of thes...

Страница 17: ...river Motors DLS Relay Relay 5 Wire Reversal Doorlocks using the Optional DLS 2 Relays DLS Violet Wire to Constant 12 Volts 3WirePositivePulseSystemsareverysimilartotheThreeWireNegative Pulse system e...

Страница 18: ...Pin Secondary Harness Backup Battery Port Slide On Clip for optional modular Backup Battery Coaxial Antenna Cable Route end as high as practical in vehicle away from metal Note May not be present or m...