background image

Page - 14

Blue Wire - (Negative Instant Trigger):

  The Blue wire is a Negative

instant trigger used to detect entry into the hood or trunk area of a vehicle.

CONNECTION:

  The included pin switches may be installed to provide this

trigger circuit; or, if there are existing switches the Blue wire may be connected
directly, provided this is a negative ground switching circuit (examples: an OEM
antitheft hood switch, or in the case of the trunk or hatch a light in the luggage
compartment or a "Trunk Ajar" light in the dash).

An indication of such a circuit is the wire having no voltage present when the

hood or trunk is open, and up to 12 volts when the hood or trunk is closed.  This wire

The Programmable Features

Page - 23

 - SEE PAGE 32 FOR PROGRAMMING INSTRUCTIONS -

Each Programmable Features is described in detail in this section, then
Programming instructions follow, which include a handy Features’
matrix showing the Features and all programming options.

This group of User Programmable Features are all accessed as a group in the first
level of features’ programming.  These features have a direct affect upon the
system’s operations, so the programming and operation of each are described.

The Excalibur AL-1010-EDP and AL-1510-EDP 

Programmable Features 

are:

  

1

SecureCode

  2

Last Door Arming

  3

Automatic  Rearming

  4

Starter Interrupt Functions

  5

Ignition Activated Override

  6

Doors Lock With Ignition On

  7

Doors Unlock With Ignition Off

  8

Open Door Bypass To Previous Two Features

  9

Confirmation Chirps

10

Confirmation Chirp Volume

11

Activated Alarm Cycle

12

Lights On Upon Disarm

13

Disarm Alarm Upon Trunk Release

14

Arming Delay

15

Steady Siren Output / Pulsed Horn

16

Alarm Functions Bypass

17

Ignition Activated Anti-Carjacking Protection

18

Door Activated Anti-Carjacking Protection

19

Remote Activated Anti-Carjacking Protection

20

Open Door Warning Upon Arming

21

III Button Operation

22

Doorlock Functions

23

(-) Parking Light Output

24

Horn Honk Output

Use the step-by-step instructions on page 32, and the complete features matrix

on page 33, to change any of the programmable features.  Each feature, the option
choices and related programming controller/transmitter button assignment are
described in detail in the following pages.

may be used with a mercury type of tilt switch, by itself, but it cannot be used with
existing hood or trunk lights which have an internal mercury switch.  If the vehicle
is equipped with a usable trunk or hood circuit, locate the proper wire and splice the
Blue wire directly to the vehicle's wire.  If not, then you can install a pin or mercury
switch and carefully adjust and test it.

Multiple use of the Blue wire:  

When wiring more than one of the vehicle's

circuits and/or additional circuits to this wire, diode-isolation is usually required to
maintain each circuit's proper independent operation.  An example would be wiring
a hood pin switch and trunk light switch together.  Without isolating, the trunk light
will illuminate whenever the hood is raised.  Also, diode-isolation is necessary when
combining electronic sensors together, or when adding a sensor in the same circuit
as the pin switches.

Blue (-) Instant Trigger Wire.

Use IN4002 Diodes to isolate
each switch or device

Trunk
   Pin
Switch

 Hood
   Pin
Switch

  Trunk
   Light

Diode-Isolating Multiple Negative Instant Triggers

Excalibur

Control
Module

Optional

Electronic

Sensor

Содержание AL-1010-EDP

Страница 1: ...is to be printed with gray scale front cover this is a place marker cover Excalibur INSTALLATION INSTRUCTIONS COPYRIGHT 2009 OMEGA RESEARCH DEVELOPMENT INC FRONT COVER PRINTER S NOTE production front...

Страница 2: ...ansceiver or Coaxial Antenna 22 Programming The Programmable Features 23 31 Programming Features 32 Programmable Features Matrix 33 Contents Omega Disclaims Any Responsibility or Liability In Connecti...

Страница 3: ...le which is mounted upon completion of the installation and testing of the system Some of the wiring connections such as power ignition and starter interrupt are best made at the ignition switch harne...

Страница 4: ...the vehicle Separate AL 1010 EDP In the case of the AL 1010 EDP or as optional parts for the AL 1510 EDP the separate Status Light and Valet Switch may be custom mounted inside the vehicle For the Sta...

Страница 5: ...ystems and accept all Omega analog doorlocking accessories dual triple relay sockets or the modular clip on add on relay packs All Omega doorlocking data bus module accessories can be driven by this p...

Страница 6: ...und is difficult to diagnose pressing the arm lock or disarm unlock button Only the output itself will stop pressing either button again will normally operate the system and at any time after the 28 s...

Страница 7: ...ure Typically a total closure feature is when locking the vehicle s doors if the key in the door is held to lock for a period of time the vehicle will close all windows and the sunroof in addition to...

Страница 8: ...s will flash 3 times instead of once Feature 17 Ignition Activated Anti Carjacking Protection Feature 21 III Button Operation Factory Default Setting 3rd Channel press arm lock button to program Thest...

Страница 9: ...tion andnot the interior light operation Page 9 Secondary Wiring Harness 8 Wire Connector Brown Wire Positive Siren Output The Brown wire is a 1 Amp Positive output designed to operate the electronic...

Страница 10: ...them for disarming confirmation to confirm remote starting and to attract attention while the system is activated CONNECTION Connect this wire to the vehicle s Positive 12 Volt parking light circuit...

Страница 11: ...nition switch is turned on An exception to this would be if feature 8 is turned on and a door being open when the ignition switch is turned on The following feature 7 controls the automatic unlocking...

Страница 12: ...12 The correct wire for a Positive switching type of dome light door jamb pin switch system will have 12 volts present when the doors are opened and chassis ground when the doors are closed CONNECTION...

Страница 13: ...and closes the door This feature turns that operation on or off and with options of having Last Door Arming operate with or without also locking the doors when the system does arm SecureCode is a uni...

Страница 14: ...3 Disarm Alarm Upon Trunk Release 14 Arming Delay 15 Steady Siren Output Pulsed Horn 16 Alarm Functions Bypass 17 Ignition Activated Anti Carjacking Protection 18 Door Activated Anti Carjacking Protec...

Страница 15: ...he exposed inner end high in the dash or behind pillar trim for the best operating range Do not place the exposed end too close to metal structural parts of the vehicle The AL 1010 EDP can be upgraded...

Страница 16: ...tch s wiring Page 21 The two later wires are both routed to the doorlock actuators and are connected to either end of the actuator s motor winding When the switch is pushed to one position one of thes...

Страница 17: ...river Motors DLS Relay Relay 5 Wire Reversal Doorlocks using the Optional DLS 2 Relays DLS Violet Wire to Constant 12 Volts 3WirePositivePulseSystemsareverysimilartotheThreeWireNegative Pulse system e...

Страница 18: ...Pin Secondary Harness Backup Battery Port Slide On Clip for optional modular Backup Battery Coaxial Antenna Cable Route end as high as practical in vehicle away from metal Note May not be present or m...

Отзывы: