Design and function
TIG Synergic operating principle
68
099-000115-EW501
17.06.2015
5.13.10 Function sequences/operating modes
Figure 5-29
Item Symbol
Description
0
1
Select welding parameters button
This button is used to select the welding parameters depending on the welding process
and operating mode used.
2
Welding parameter setting rotary transducer
Setting of all parameters such as welding current, sheet metal thickness, gas pre-flow
time, etc.
5.13.10.1 Explanation of symbols
Symbol
Meaning
Press torch trigger 1
Release torch trigger 1
I
Current
t
Time
Gas pre-flows
I
start
Ignition current
t
Up
Up-slope time
tP
Spot time
AMP
Main current (minimum to maximum current)
AMP%
Secondary current (0% to 100% of AMP)
t1
Pulse time
t2
Pulse pause time
ts1
TIG pulses: Slop time from main current (AMP) to secondary current (AMP%)
ts2
TIG pulses: Slop time from secondary current (AMP%) to main current (AMP)
t
Down
Down-slope time
I
end
End-crater current
Gas post-flows
Содержание Tetrix 351
Страница 7: ...Contents Notes on the use of these operating instructions 099 000115 EW501 17 06 2015 7...
Страница 22: ...Machine description quick overview Rear view 22 099 000115 EW501 17 06 2015 4 4 Rear view Figure 4 3...
Страница 26: ...Machine description quick overview Rear view 26 099 000115 EW501 17 06 2015 4 7 Rear view Figure 4 5...
Страница 111: ...Design and function Machine configuration menu 099 000115 EW501 17 06 2015 111 EXIT NAVIGATION ENTER l 0 Figure 5 55...
Страница 138: ...Appendix B Overview of EWM branches 138 099 000115 EW501 17 06 2015 11 Appendix B 11 1 Overview of EWM branches...