Design and function
TIG cold wire welding
44
099-000115-EW501
17.06.2015
• Insert the end of the hose package through the strain relief of the hose package and lock by turning to
the right.
• Push the cable plug for the welding current (TIG) onto the connection socket (TIG) and lock by turning
to the right.
• Insert cable plug on the control lead into the connection socket (28-pole) and secure with crown nut
(the plug can only be inserted into the connection socket in one position).
• Lock connecting nipples of the cooling water tubes into the corresponding quick connect couplings:
Return line red to quick connect coupling, red (coolant return) and
supply line blue to quick connect coupling, blue (coolant supply).
• Screw the crown nut on the shielding gas lead gastight to the connecting thread (G¼").
Содержание Tetrix 351
Страница 7: ...Contents Notes on the use of these operating instructions 099 000115 EW501 17 06 2015 7...
Страница 22: ...Machine description quick overview Rear view 22 099 000115 EW501 17 06 2015 4 4 Rear view Figure 4 3...
Страница 26: ...Machine description quick overview Rear view 26 099 000115 EW501 17 06 2015 4 7 Rear view Figure 4 5...
Страница 111: ...Design and function Machine configuration menu 099 000115 EW501 17 06 2015 111 EXIT NAVIGATION ENTER l 0 Figure 5 55...