Design and function
Configuring the welding machine for mechanical arc fusion welding
099-000115-EW501
17.06.2015
53
Display
Setting/selection
Filler wire diameter (manual setting)
Setting of the wire diameter from 0.6 mm to 1.6 mm.
The character "d" preceding the wire diameter on the display (d0.8) indicates a pre-
programmed characteristics (operating mode KORREKTUR).
If there is no characteristics for the selected wire diameter, the parameters have to be set
manually (operating mode MANUELL).
For information on how to select the operating mode- See 5.11.2 Select wire speed
operating mode (KORREKTUR / MANUELL) chapter.
Wire return
• Increase value = more wire return
• Reduce value = less wire return
Parameter can also be set after connecting a TIG cold wire feed unit. Setting: 0 to 255
(factory setting 50).
Please note the relevant documentation of the accessory components.
5.11.1 Selecting a welding task by means of the JOB list
• Select material, tungsten electrode
and seam position on the welding machine controls.
The welding task number (JOB number) results from the chosen basic parameters. If no wire
speed is assigned to this JOB-number (- See 10.1 JOB-List chapter), wire feeding will not take
place. In order to carry out the chosen welding task, the wire feed unit must be switched to the
MANUELL operating mode - See 5.11.2 Select wire speed operating mode (KORREKTUR /
MANUELL) chapter.
5.11.2 Select wire speed operating mode (KORREKTUR / MANUELL)
The wire speed can be set in two different operating modes:
MANUAL:
The wire speed can be selected on the wire feed unit as an absolute value across the
entire setting range.
CORRETION:
The wire speed is approximately specified by the welding machine control and can be
corrected as a percentage on the wire feed unit
In the wire feed unit underneath the cap is a switch for selecting the operating mode.
5.11.3 Setting the welding current and wire speed
Operating
element
Action
Result
Set welding current on the welding machine
Set wire speed
MANUAL operating mode (outer scale):
The wire speed can be selected on the wire feed unit as an absolute
value across the entire setting range.
CORRECTION operating mode (inner scale):
The wire speed is specified largely by the welding machine control and
can be corrected as a percentage on the wire feed unit
Содержание Tetrix 351
Страница 7: ...Contents Notes on the use of these operating instructions 099 000115 EW501 17 06 2015 7...
Страница 22: ...Machine description quick overview Rear view 22 099 000115 EW501 17 06 2015 4 4 Rear view Figure 4 3...
Страница 26: ...Machine description quick overview Rear view 26 099 000115 EW501 17 06 2015 4 7 Rear view Figure 4 5...
Страница 111: ...Design and function Machine configuration menu 099 000115 EW501 17 06 2015 111 EXIT NAVIGATION ENTER l 0 Figure 5 55...
Страница 138: ...Appendix B Overview of EWM branches 138 099 000115 EW501 17 06 2015 11 Appendix B 11 1 Overview of EWM branches...