Design and function
TIG Synergic operating principle
099-000115-EW501
17.06.2015
61
5.13.2.1 Set the operating principle (conventional/synergic)
NAVIGATION
ENTER
+
EXIT
l
0
Figure 5-24
Display
Setting/selection
Exit the menu
Exit
Machine configuration
Settings for machine functions and parameter display
Operating principle
• on = synergic parameter setting (factory setting)
• off = conventional parameter setting
ENTER (enter the menu)
• Switch off machine at the main switch
• Press and hold the "welding parameters" button and switch the machine on again at the same
time.
NAVIGATION (navigating in the menu)
• Parameters are selected by pressing the "welding parameters" button.
• Set or change the parameters by turning the "welding parameter setting" rotary dial.
EXIT (leave the menu)
• Select the "Elt" menu item.
• Press the "welding parameters" button (settings will be applied, machine changes to the
ready-to-operate status).