Design and function
MIG/MAG welding
66
099-005323-EW501
21.05.2014
5.8.11.2
MIG/MAG
overview of parameters
NOTE
P
START
, P
B
, and P
END
are set as relative programs ex faxtory. They relate to percentages
of the wire feed value of the main program P
A
. These programs can also be set in an
absolute manner, if desired (see Setting of special parameter P21).
Figure 5-30
Basic Parameters
Item
Meaning / Explanation
Setting Range
1
1
Gas pre-flow time
0.0s to 20.0s
2
2
P
START
Wire speed, relative
Arc length correction
1% to 200%
-9.9V to +9.9V
3
3
Duration
0.0s to 20.0s
4
4
Slope duration from P
START
to P
A
0.0s to 20.0s
5
5
P
A
Wire speed, absolute
0.1 m/min to 40 m/min
6
7
Duration (spot time and superpulse)
0.01s to 20.0s
7
8
P
B
Wire speed, relative
Arc length correction, relative
1% to 200%
-9.9V to +9.9V
8
9
Duration
0.01s to 20.0s
9
1
0
Slope duration from P
A
to P
END
0.0s to 20s
10
1
1
P
END
Wire speed, relative
Arc length correction
1% to 200%
-9.9V to +9.9V
11
1
2
Duration (superpulse)
0.0s to 20s
12
1
3
Gas post-flow time
0.0s to 20s
13
1
4
Superpulses
On / Off
Содержание Phoenix 401 Progress puls MM FKW
Страница 6: ...Contents Notes on the use of these operating instructions 6 099 005323 EW501 21 05 2014...
Страница 20: ...Machine description quick overview Rear view 20 099 005323 EW501 21 05 2014 4 2 Rear view Figure 4 2...
Страница 22: ...Machine description quick overview Inside view 22 099 005323 EW501 21 05 2014 4 3 Inside view Figure 4 3...
Страница 122: ...Appendix A JOB List 122 099 005323 EW501 21 05 2014 11 Appendix A 11 1 JOB List Figure 11 1...
Страница 123: ...Appendix B Overview of EWM branches 099 005323 EW501 21 05 2014 123 12 Appendix B 12 1 Overview of EWM branches...