Design and function
Interfaces for automation
82
099-005403-EW501
10.2.2022
5.9.1 Automation interface
WARNING
No function of the external interrupt equipment (emergency stop switch)!
If the emergency stop circuit has been set up using an external interrupt equipment
connected to the interface for automated welding, the machine must be configured for
this setup. If this is not observed, the power source will ignore the external interrupt
equipment and will not shut down!
• Remove jumper 1 on the corresponding control board (to be done only by qualified service
personnel)!
Pin
Input /
Output
Name
Figure
A
Output
PE -------- Connection for cable screen
D
Output
(open collec-
tor)
IGRO ---- Current flows signal I>0 (maximum load 20 mA /
15 V) 0 V = welding current flows
E/R
Input
Not-Aus - Emergency stop for higher level shut-down of the
power source.
F
Output
0V -------- Reference potential
G/P
Output
IGRO ---- Current relay contact to the user, potential-free
(max. +/-15 V / 100 mA)
H
Output
Uist ------- Welding voltage measured against pin F, 0-10 V
(0 V = 0 V; 10 V = 100 V)
[1]
L
Input
STA/STP Start = 15 V / Stop = 0 V
[2]
M
Output
+15 V ---- Power supply (max. 75 mA)
N
Output
-15 V ----- Power supply (max. 25 mA)
S
Output
0 V ------- Reference potential
T
Output
Iist -------- Welding current measured against pin F;
0-10 V (0 V = 0 A, 10 V = 1000 A)
[3]
[1]
Accuracy type ± (0.05 V+2.5 % of the measured value)
[2]
The operating mode is specified by the wire feeder (the start / stop function corresponds to the opera-
tion of the torch trigger and is used, for instance, in mechanized applications).
[3]
Accuracy type ± (0.02 V+2.5 % of the measured value)