Design and function
Special parameters (advanced settings)
099-005403-EW501
10.2.2022
85
5.11.1 Selecting, changing and saving parameters
B
A
A
l
0
+
B
A
A
B
Figure 5-79
Display
Setting/selection
Wire inching / wire return ramp time
0 = --------normal inching (10 s ramp time)
1 = --------fast inching (3 s ramp time) (ex works)
Block program "0"
0 = --------P0 enabled
1 = --------P0 blocked (Ex works)
Display mode for Up/Down welding torch with one-digit 7-segment display (two
keys)
0 = --------normal display (ex works) program number/welding power (0–9)
1 = --------display toggles between program number/welding type
Program limitation
Programs 1 to max. 15
Ex works: 15
Special cycle in the special latched and non-latched operating modes
0 = --------normal (previous) non-latched/latched (Ex works)
1 = --------WF3 cycle for non-latched/latched
Enable special jobs SP1 to SP3
0 = --------no enabling (Ex works)
1 = --------enabling of Sp1-3
Correction operation, threshold value setting
0 = --------correction operation switched off (Ex works)
1 = --------correction operation on
"Main program (PA)" flashing
Program switching with standard welding torch
0 =
No program switching (factory setting)
1 = --------Special latched
2 = --------Special latched (n-cycle active)
3 = --------Special latched (n-cycle sequence from any program)