202
WT.050.580.000.DE.IM.0714
Installation
MFC
6.
6.4
Decommissioning
Caution!
Danger of uncontrolled dosing of chlorine or pH
correction medium: Shut down dosing system, close positioner!
If the installation site of the flow block assembly is not frost-free,
the system must be shut down in due time!
1
Switch off the power supply.
2
Drain the sample water supply line and drainage line (hold
container underneath)
3
Empty cell bodies and remove cleaning sand (see “Replacing
cell sand in DEPOLOX® 5 three-electrode cell" on page 205).
4
Dismantle the filter housing and the check valve housing.
5
When the remaining water has drained from the flow control
valve, refit the filter housing and the check valve housing.
6
Remove the sensors from the cell body cover and disconnect
from the cable (see 4.2.6 “Membrane sensors" on page 56).
7
Apply a KCI solution to the protection caps of the pH and
Redox electrodes and fit onto the electrodes.
Please note
A "KCI tank to store the sensors" may be used instead of the
protection cap for pH and Redox electrodes (see 8. “Complete
Devices, Retrofit Kits and Spare Parts" on page 215).
The fluoride electrodes can be stored wet in the short term in a
100 mg/l fluoride solution at pH 7. Fill the electrodes in the
tank with 100 mg/l fluoride solution and mount on the
electrodes. However, the electrodes should be stored in a dry
condition if to be warehoused for several months. In this case,
drain the fill solution from the electrode chamber and wash the
membrane and chamber with distilled water.
8
Store the sensors in a frost-free place.
Please note
The water must be drained if frost occurs. Insert electrode in a
beaker with water and store in a frost-free place.
9
Procedure for membrane sensors, see 4.2.6 “Membrane
sensors" on page 56.
A
B
C
D
E
A Sensor
B Sealing cap
C O-ring
D Tank
E Stand
Содержание WALLACE & TIERNAN MFC
Страница 1: ...WALLACE TIERNAN MULTI FUNCTION CONTROLLER MFC from version V 2 00 INSTRUCTION MANUAL...
Страница 2: ...2 WT 050 580 000 DE IM 0714 MFC Please note Original manual...
Страница 6: ...6 WT 050 580 000 DE IM 0714 Introduction MFC 1...
Страница 40: ...40 WT 050 580 000 DE IM 0714 Description MFC 3...
Страница 225: ...MFC Complete Devices Retrofit Kits and Spare Parts 8 225 DEPOLOX 5 drawing non pressurised version W3T170031 W3T170031...
Страница 229: ...MFC Complete Devices Retrofit Kits and Spare Parts 8 229 DEPOLOX 5 drawing pressurised version W3T170032 W3T170032...
Страница 233: ...MFC Complete Devices Retrofit Kits and Spare Parts 8 233 VariaSens drawing non pressurised version W3T158742 W3T158742...
Страница 237: ...MFC Complete Devices Retrofit Kits and Spare Parts 8 237 VariaSens drawing pressurised version W3T158756 W3T158756...
Страница 247: ...MFC Certificates 10 247 10 Certificates...
Страница 248: ...248 WT 050 580 000 DE IM 0714 Certificates MFC 10...
Страница 249: ...MFC Certificates 10 249...
Страница 250: ...250 WT 050 580 000 DE IM 0714 Certificates MFC 10...
Страница 262: ...262 WT 050 580 000 DE IM 0714 Settings table MFC 11...
Страница 266: ...266 WT 050 580 000 DE IM 0714 Index MFC 12...